{"id":6063,"date":"2023-08-08T14:18:50","date_gmt":"2023-08-08T06:18:50","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6063"},"modified":"2025-04-18T14:00:46","modified_gmt":"2025-04-18T06:00:46","slug":"calibrate-4-20ma-input","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/pt_pt\/support\/how-to-actuator\/calibrate-4-20ma-input","title":{"rendered":"Como calibrate (calibrar) o sinal de entrada do atuador?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6063\" class=\"elementor elementor-6063\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-05aec29 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"05aec29\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dc31e3\" data-id=\"4dc31e3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11f2047 elementor-widget elementor-widget-text-editor\" data-id=\"11f2047\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Quando a entrada \u00e9 de 4~20mA, h\u00e1 um desvio entre a posi\u00e7\u00e3o da v\u00e1lvula e o sinal de entrada posicionado pelo atuador (neste momento, o sinal de realimenta\u00e7\u00e3o e o sinal de entrada tamb\u00e9m s\u00e3o tendenciosas), voc\u00ea pode calibrate (calibrar) o sinal de entrada do atuador para eliminar esse desvio.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73c3568 elementor-widget elementor-widget-image\" data-id=\"73c3568\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"446\" height=\"374\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-hysteresis-value-of-actuator\/set-actuator-hysteresis.webp\" class=\"attachment-full size-full wp-image-4999\" alt=\"\u8bbe\u7f6e\u6b66\u6c49\u534e\u6613\u7535\u52a8\u6267\u884c\u5668\u7684\u6b7b\u533a | Setting Hysteresis of DCL Actuator\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-hysteresis-value-of-actuator\/set-actuator-hysteresis.webp 446w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-hysteresis-value-of-actuator\/set-actuator-hysteresis-300x252.webp 300w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-hysteresis-value-of-actuator\/set-actuator-hysteresis-14x12.webp 14w\" sizes=\"(max-width: 446px) 100vw, 446px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-54175ec elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"54175ec\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c437fc7\" data-id=\"c437fc7\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3f9d45a elementor-widget elementor-widget-image\" data-id=\"3f9d45a\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"606\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-up-a-servo-type-electric-actuator-valve\/images\/sf-zc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5320\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u9600 \u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-up-a-servo-type-electric-actuator-valve\/images\/sf-zc-servo-control-pack-cn.webp 600w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-up-a-servo-type-electric-actuator-valve\/images\/sf-zc-servo-control-pack-cn-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-5b79a39\" data-id=\"5b79a39\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bef6a51 elementor-widget elementor-widget-image\" data-id=\"bef6a51\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"599\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-up-a-servo-type-electric-actuator-valve\/images\/sf-lc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5318\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u6267\u884c\u5668 LC\u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-up-a-servo-type-electric-actuator-valve\/images\/sf-lc-servo-control-pack-cn.webp 600w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-set-up-a-servo-type-electric-actuator-valve\/images\/sf-lc-servo-control-pack-cn-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-b95f9a4 elementor-widget elementor-widget-text-editor\" data-id=\"b95f9a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Apenas 5 passos s\u00e3o necess\u00e1rios\uff1a<\/p><ol><li>Parafuso S-Uma para a 2\u00aa marcha.<\/li><li>Pressione e segure o bot\u00e3o Set at\u00e9 o L2 luz vermelha acende-se. (L2 pisca ap\u00f3s o lan\u00e7amento)<\/li><li>Pressione e mantenha Aberta e Fechada ao mesmo tempo, dentro de 5 anos, e a L2 cintila\u00e7\u00e3o vai mudar para a L3 de cintila\u00e7\u00e3o. Neste momento, o m\u00f3dulo de controle de entra no modo de entrada do sinal de calibra\u00e7\u00e3o (calibra\u00e7\u00e3o).<\/li><li>Utilizar a fonte de sinal para a entrada de 4mA, e pressione e mantenha pressionado Set e Fecharam ao mesmo tempo, at\u00e9 L4) acende-se e a 4mA de calibra\u00e7\u00e3o (calibra\u00e7\u00e3o) \u00e9 conclu\u00edda.<\/li><li>Utilizar a fonte de sinal de entrada 20mA, e pressione e mantenha pressionado Set e Fecharam ao mesmo tempo, at\u00e9 L4) acende-se e a 20mA calibra\u00e7\u00e3o (calibra\u00e7\u00e3o) \u00e9 conclu\u00edda.<\/li><li>Pressione e segure o bot\u00e3o Set at\u00e9 L3 p\u00e1ra de piscar e desaparece. O m\u00f3dulo de sa\u00eddas o sinal de entrada de calibra\u00e7\u00e3o (calibra\u00e7\u00e3o) de modo.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8dc932e elementor-widget elementor-widget-text-editor\" data-id=\"8dc932e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Opera\u00e7\u00e3o de tela de v\u00eddeo&gt;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-15ff962 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"15ff962\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0f8923d\" data-id=\"0f8923d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d50dfba elementor-widget elementor-widget-heading\" data-id=\"d50dfba\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/pt_pt\/tech\/set-up-dcl-actuator\/\">Anterior: Como configurar um ajuste de v\u00e1lvula el\u00e9trica?<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-eb73e3e\" data-id=\"eb73e3e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c7625bd elementor-widget elementor-widget-heading\" data-id=\"c7625bd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/pt_pt\/tech\/set-hysteresis\/\">Pr\u00f3ximo: Como definir a zona morta do atuador?<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u5f53\u8f93\u51654~20mA\u65f6\uff0c\u6267\u884c\u5668\u5b9a\u4f4d\u7684\u9600\u4f4d\u548c\u8f93\u5165\u4fe1\u53f7\u5b58\u5728\u504f\u5dee\u65f6\uff08\u6b64\u65f6\uff0c\u53cd\u9988\u4fe1\u53f7\u548c\u8f93\u5165\u4fe1\u53f7\u4e5f\u5b58\u5728\u504f\u5dee\uff09\uff0c\u60a8\u53ef\u4ee5\u901a\u8fc7\u5bf9 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5319,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[648],"tags":[44,34,393,42,377,373,41],"class_list":["post-6063","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-fast-move-actuator","tag-actuator","tag-user-manual","tag-general-actuator","tag-servo-actuator","tag-very-small-actuator-tag","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=6063"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6063\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/media\/5319"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=6063"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=6063"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=6063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}