{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-04-18T11:35:25","modified_gmt":"2025-04-18T03:35:25","slug":"dcl-02-servo","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/pt_pt\/support\/mr-actuator\/dcl-02-servo","title":{"rendered":"Falhas comuns e solu\u00e7\u00e3o de problemas de DCL-02 ajust\u00e1vel atuador"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0b92fb9 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"0b92fb9\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a0e43d9\" data-id=\"a0e43d9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9c2fac6 elementor-widget elementor-widget-text-editor\" data-id=\"9c2fac6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este assistente \u00e9 adequado para DCL Jingxiao s\u00e9rie de atuadores, os modelos s\u00e3o os seguintes:<\/p><ul><li>DCL-02E<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ca542fe elementor-widget elementor-widget-image\" data-id=\"ca542fe\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Actuators\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp 696w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-300x259.webp 300w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-14x12.webp 14w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06941c9 elementor-widget elementor-widget-heading\" data-id=\"06941c9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Falhas comuns e m\u00e9todos de solu\u00e7\u00e3o de problemas.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5bedff elementor-widget elementor-widget-shortcode\" data-id=\"b5bedff\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-36\" class=\"tablepress tablepress-id-36 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">\u6545\u969c<\/th><th class=\"column-2\">\u53ef\u80fd\u7684\u539f\u56e0<\/th><th class=\"column-3\">\u6392\u9664\u65b9\u6cd5<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\">O atuador n\u00e3o ligar ou desligar quando \u00e9 iniciado pela primeira vez<\/td><td class=\"column-2\">1. \u63a5\u7ebf\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">\u6309\u7167\u6267\u884c\u5668\u7684\u63a5\u7ebf\u56fe\u6838\u5bf9\u63a5\u7ebf\u662f\u5426\u6b63\u786e\uff1f<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. \u4f9b\u7535\u7535\u6e90\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">\u786e\u8ba4\u4f9b\u7535\u7535\u6e90\u7684\u8f93\u51fa\u7535\u538b\u4e3a\u6267\u884c\u5668\u989d\u5b9a\u7535\u538b\u7684\u00b110%\uff0c\u8f93\u51fa\u7535\u6d41\u4e3a\u6267\u884c\u5668\u989d\u5b9a\u7535\u6d41\u76843\u500d\u3002<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. \u63a7\u5236\u5f00\u5173\u6216\u63a7\u5236\u7ee7\u7535\u5668\u5f02\u5e38<\/td><td class=\"column-3\">\u4f7f\u7528\u4e07\u7528\u8868\u6d4b\u91cf\u6267\u884c\u5668\u5f00\u5173\u63a7\u5236\u7aef\u7684\u8f93\u5165\u7535\u538b\uff0c\u786e\u8ba4\u662f\u5426\u7b26\u5408\u9884\u671f\uff1f<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. Sistema de controle de problema de correspond\u00eancia de<\/td><td class=\"column-3\">Usar um interruptor mec\u00e2nico para medir a fun\u00e7\u00e3o do atuador. Se o atuador estiver funcionando normalmente, verifique se a sa\u00edda l\u00f3gica do sistema de controle atende as expectativas?<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. V\u00e1rios atuadores ou atuadores em paralelo com outros equipamentos<\/td><td class=\"column-3\">O actuador de comuta\u00e7\u00e3o \u00e9 iniciado atrav\u00e9s do capacitor de partida, e fazendo um paralelo com outros equipamentos ter\u00e3o um impacto sobre o valor da capacit\u00e2ncia do capacitor de partida. Portanto, o actuador de comuta\u00e7\u00e3o pode usar apenas um \u00fanico controle, n\u00e3o em paralelo.<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td rowspan=\"2\" class=\"column-1\">O atuador pode apenas ser ligado ou desligado<\/td><td class=\"column-2\">1. \u63a5\u7ebf\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">1. Usar um interruptor mec\u00e2nico para medir a fun\u00e7\u00e3o do atuador. Se o atuador estiver funcionando normalmente, verifique se a sa\u00edda l\u00f3gica do sistema de controle atende as expectativas?<br \/>\n2. Verifique se a fia\u00e7\u00e3o est\u00e1 correta, de acordo com o diagrama de liga\u00e7\u00f5es do atuador?<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-2\">2. Configura\u00e7\u00e3o incorreta de totalmente on\/fullyoff cam<\/td><td class=\"column-3\">refer\u00eancia<a href=\"\/pt_pt\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Como configurar um switch tipo de v\u00e1lvula El\u00e9trica&#034;<\/a>, Definir a posi\u00e7\u00e3o da c\u00e2mara corretamente.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td rowspan=\"3\" class=\"column-1\">O atuador p\u00e1ra no meio da viagem<\/td><td class=\"column-2\">1. V\u00e1lvula de estagna\u00e7\u00e3o<\/td><td class=\"column-3\">Verificar se a v\u00e1lvula est\u00e1 preso, eliminar o preso, e tente novamente depois que o atuador \u00e9 arrefecido por meio de prote\u00e7\u00e3o contra sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">2. Potencial de s\u00f3lidos no l\u00edquido m\u00e9dio causar a v\u00e1lvula de estagna\u00e7\u00e3o.<\/td><td class=\"column-3\">Verifique se h\u00e1 s\u00f3lidos preso no meio fluido, eliminam a v\u00e1lvula presa e tente novamente depois que o atuador \u00e9 arrefecido por meio de prote\u00e7\u00e3o contra sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">3. Configura\u00e7\u00e3o incorreta de totalmente ligado\/totalmente desligado rolha<\/td><td class=\"column-3\">refer\u00eancia<a href=\"\/pt_pt\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Como configurar um switch tipo de v\u00e1lvula El\u00e9trica&#034;<\/a>, Definir o batente de posi\u00e7\u00e3o corretamente.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Usando a al\u00e7a, o atuador n\u00e3o pode ser girado<\/td><td class=\"column-2\">1. Potencial de s\u00f3lidos no l\u00edquido m\u00e9dio causar a v\u00e1lvula para ficar preso.<\/td><td class=\"column-3\">Verifique se h\u00e1 s\u00f3lidos preso no meio fluido, eliminam a v\u00e1lvula presa e tente novamente depois que o atuador \u00e9 arrefecido por meio de prote\u00e7\u00e3o contra sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. V\u00e1lvula preso<\/td><td class=\"column-3\">Verificar se a v\u00e1lvula est\u00e1 preso, eliminar o preso, e tente novamente depois que o atuador \u00e9 arrefecido por meio de prote\u00e7\u00e3o contra sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. O atuador de desacelera\u00e7\u00e3o mecanismo est\u00e1 danificado.<\/td><td class=\"column-3\">Remova o atuador da v\u00e1lvula e gire a manivela. Se ele n\u00e3o pode ser girado, substitu\u00ed-lo com um novo atuador.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Posi\u00e7\u00e3o do sinal de realimenta\u00e7\u00e3o sem sa\u00edda<\/td><td class=\"column-2\">1. Op\u00e7\u00e3o incorreta fia\u00e7\u00e3o<\/td><td class=\"column-3\">\u6309\u7167\u6267\u884c\u5668\u7684\u63a5\u7ebf\u56fe\u6838\u5bf9\u63a5\u7ebf\u662f\u5426\u6b63\u786e\uff1f<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. Configura\u00e7\u00e3o incorreta de totalmente on\/fullyoff cam<\/td><td class=\"column-3\">refer\u00eancia<a href=\"\/pt_pt\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Como configurar um switch tipo de v\u00e1lvula El\u00e9trica&#034;<\/a>, Definir a posi\u00e7\u00e3o da c\u00e2mara corretamente.<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. Sobrecorrente causa dano para o interruptor do sinal de realimenta\u00e7\u00e3o de posi\u00e7\u00e3o.<\/td><td class=\"column-3\">1. refer\u00eancia<a href=\"\/pt_pt\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Como configurar um switch tipo de v\u00e1lvula El\u00e9trica&#034;<\/a>, Verifique se totalmente em\/fullyoff cam compacta o feedback da posi\u00e7\u00e3o do interruptor?<br \/>\n2. \u00c9 a posi\u00e7\u00e3o de medi\u00e7\u00e3o ciclo de feedback ligado?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-36 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d23775 elementor-widget elementor-widget-heading\" data-id=\"3d23775\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Por favor, verifique se o aplicativo condi\u00e7\u00f5es de atender os requisitos de par\u00e2metro.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae37bb6 elementor-widget elementor-widget-text-editor\" data-id=\"ae37bb6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 O atuador el\u00e9trico pode falhar devido \u00e0 utiliza\u00e7\u00e3o inadequada ou em errado condi\u00e7\u00f5es de aplica\u00e7\u00e3o. Sob as condi\u00e7\u00f5es de aplica\u00e7\u00e3o definidos na especifica\u00e7\u00e3o do produto, a longo prazo, livre de problemas de opera\u00e7\u00e3o do atuador ser\u00e1 assegurada.<\/p><ul><li><strong>Fonte de tens\u00e3o:<\/strong>A tens\u00e3o da fonte de alimenta\u00e7\u00e3o deve estar dentro da faixa de faixa de tens\u00e3o de opera\u00e7\u00e3o do atuador. Sobretens\u00e3o ou subtens\u00e3o, pode causar a vida \u00fatil do atuador seja reduzido.<\/li><li><span style=\"font-weight: bold;\">Oferta atual:<\/span>Desde que a corrente de partida do motor \u00e9 muito maior do que a corrente nominal. Para garantir o funcionamento fi\u00e1vel do atuador, por favor, utilize uma fonte de alimenta\u00e7\u00e3o com uma capacidade de corrente de sa\u00edda superior a 3 vezes a corrente nominal do atuador.<\/li><li><strong>temperatura\uff1a<\/strong>Assegurar que o atuador est\u00e1 operando dentro da faixa de temperatura de funcionamento intervalo. O uso do atuador em um ambiente que exceder o nominal, faixa de temperatura de opera\u00e7\u00e3o pode levar a baixa do atuador fun\u00e7\u00e3o ou redu\u00e7\u00e3o da vida \u00fatil, e, finalmente, levar \u00e0 falha do atuador.<\/li><li><strong>ambiente\uff1a<\/strong>A DCL mudar o tipo de atuador tem um IP67 \u00e0 prova de intemp\u00e9ries de classifica\u00e7\u00e3o. Em geral, adequado para interior ou exterior aplica\u00e7\u00f5es. Proporcionar um certo grau de chuva e prote\u00e7\u00e3o contra respingos. Proteger o atuador de chuva, de neve, gelo e luz ultravioleta (luz solar) geralmente prolonga a vida \u00fatil do produto. Muito corrosivo, pode causar a falha prematura de equipamentos eletr\u00f4nicos. N\u00e3o uso n\u00e3o-\u00e0 prova de explos\u00e3o s\u00e9rie de atuadores em uma prova de explos\u00e3o ambiente.<\/li><li><strong>Poder-se na continuidade taxa de\uff1a<\/strong>O poder-em continuidade taxa da DCL actuador de comuta\u00e7\u00e3o \u00e9 de 70% (executado por 42 segundos por minuto e deve ser desligado por 18 segundos). Mais de 70% da energia-em continuidade taxa far\u00e1 com que o motor entrar prote\u00e7\u00e3o de superaquecimento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d27c28 elementor-widget elementor-widget-heading\" data-id=\"5d27c28\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Verifique se a fia\u00e7\u00e3o do atuador \u00e9 correto<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-55f1331 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"55f1331\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fbc0cc2\" data-id=\"fbc0cc2\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-76cdde0 elementor-widget elementor-widget-heading\" data-id=\"76cdde0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo E: com servo-controlador (tipo ajust\u00e1vel)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75b00a4 elementor-widget elementor-widget-image\" data-id=\"75b00a4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e-15x12.webp 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2577464 elementor-widget elementor-widget-text-editor\" data-id=\"2577464\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Entrada: 4~20mA \/ 0~10V arbitr\u00e1rio de configura\u00e7\u00e3o.<\/p><p>Sa\u00edda: 4~20 ma \/ 0~10V arbitr\u00e1rio de configura\u00e7\u00e3o.<\/p><p>\u00d4nibus: Modbus \/ PODE<\/p><p>Internet das Coisas: wi-FI\/LoRA\/4G DTU<\/p><p><strong>Instru\u00e7\u00f5es de liga\u00e7\u00e3o\uff1a<\/strong><br \/>1. O &#034;N&#034; na entrada do &#034;fornecimento de ENERGIA&#034; est\u00e1 ligado \u00e0 linha do meio, e o &#034;L&#034; est\u00e1 ligado \u00e0 fase de linha.\uff1b<br \/>2. O &#034;sinal de entrada&#034; terminal \u00e9 conectado ao p\u00f3lo negativo do sinal de entrada e o sinal de &#034;+&#034; terminal \u00e9 conectado ao p\u00f3lo positivo do sinal de entrada.\uff1b<br \/>3. O &#034;sinal de sa\u00edda&#034; terminal \u00e9 conectado ao eletrodo negativo do amper\u00edmetro CC, e o &#034;+&#034; terminal \u00e9 conectado ao eletrodo positivo do amper\u00edmetro CC.<\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-efd536a\" data-id=\"efd536a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9da316 elementor-widget elementor-widget-text-editor\" data-id=\"f9da316\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Quando voc\u00ea realizar uma investiga\u00e7\u00e3o no local do projeto, voc\u00ea pode contatar nossa empresa de pessoal do servi\u00e7o t\u00e9cnico mais r\u00e1pido poss\u00edvel para investigar as falhas e determinar a solu\u00e7\u00e3o.<\/em><br \/><em>N\u00famero para contato: 13026331611 (Cheng Gong)<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u7cbe\u5c0f\u7cfb\u5217\u7684\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a DCL-02E 1\u3001\u5e38\u89c1\u6545\u969c\u53ca\u6545\u969c\u5206\u6392\u9664\u65b9\u6cd5\u3002 2\u3001\u8bf7\u6838\u5bf9\u5e94\u7528 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5251,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[374,376,387,34,373],"class_list":["post-6034","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-dcl-02","tag-dcl-02-pos","tag-trouble-shooting-guide","tag-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/media\/5251"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}