{"id":6032,"date":"2023-08-03T20:13:29","date_gmt":"2023-08-03T12:13:29","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6032"},"modified":"2025-04-18T11:35:15","modified_gmt":"2025-04-18T03:35:15","slug":"switch-actuator","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/pl_pl\/support\/mr-actuator\/switch-actuator","title":{"rendered":"Typowe usterki oraz rozwi\u0105zywanie problem\u00f3w prze\u0142\u0105czaj\u0105cych nap\u0119d\u00f3w"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6032\" class=\"elementor elementor-6032\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fe621b5 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"fe621b5\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a1fea6d\" data-id=\"a1fea6d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-49fc89d elementor-widget elementor-widget-text-editor\" data-id=\"49fc89d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kreator ten nadaje si\u0119 do prze\u0142\u0105czaj\u0105cych nap\u0119d\u00f3w \u0432\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u043e\u0439 serii DCL \/ zwyk\u0142ej serii \/ seria z szybkim otwarciem. Przedstawione s\u0105 nast\u0119puj\u0105ce modele\uff1a<\/p><ul><li>Zwyk\u0142a seria: DCL-05\/DCL-10\/DCL-20\/DCL-40\/DCL-60\/DCL-100\/DCL-160\/DCL-250<\/li><li>\u0412\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u0430\u044f seria: DCL-Ex05\/DCL-Ex10\/DCL-Ex20\/DCL-Ex40\/DCL-Ex60<\/li><li>Seria szybkiego otwierania: DCL-L05\/DCL-K10\/DCL-K20\/DCL-K40\/DCL-K100<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e165a97 elementor-widget elementor-widget-heading\" data-id=\"e165a97\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Typowe usterki i sposoby rozwi\u0105zywania problem\u00f3w.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e767e9 elementor-widget elementor-widget-shortcode\" data-id=\"0e767e9\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-31\" class=\"tablepress tablepress-id-31 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">usterka<\/th><th class=\"column-2\">Mo\u017cliwa przyczyna<\/th><th class=\"column-3\">Metoda wy\u0142\u0105czenia<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\">Nap\u0119d nie w\u0142\u0105cza i nie wy\u0142\u0105cza si\u0119 przy pierwszym uruchomieniu<\/td><td class=\"column-2\">1. Nieprawid\u0142owe okablowanie<\/td><td class=\"column-3\">Sprawd\u017a poprawno\u015b\u0107 pod\u0142\u0105czenia zgodnie ze schematem pod\u0142\u0105czenia nap\u0119du?<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. Z\u0142y zasilacz<\/td><td class=\"column-3\">Upewnij si\u0119, \u017ce napi\u0119cie \u017ar\u00f3d\u0142a zasilania wynosi \u00b1 10% napi\u0119cia znamionowego nap\u0119du, a pr\u0105d wyj\u015bciowy 3 razy wi\u0119kszy ni\u017c pr\u0105d znamionowy nap\u0119du.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. Normalny prze\u0142\u0105cznik lub przeka\u017anik steruj\u0105cy<\/td><td class=\"column-3\">U\u017cyj multimetr do pomiaru napi\u0119cia na zacisku prze\u0142\u0105cznik sterowania nap\u0119du, aby potwierdzi\u0107, czy spe\u0142nia ono oczekiwania?<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. Problem z doborem systemu zarz\u0105dzania<\/td><td class=\"column-3\">U\u017cyj mechaniczny prze\u0142\u0105cznik do pomiaru funkcji nap\u0119du. Je\u015bli nap\u0119d dzia\u0142a poprawnie, nale\u017cy sprawdzi\u0107, czy logika wyj\u015bcia systemu zarz\u0105dzania oczekiwania?<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. Kilka element\u00f3w wykonawczych lub element\u00f3w wykonawczych, dzia\u0142aj\u0105cych r\u00f3wnolegle z innym sprz\u0119tem<\/td><td class=\"column-3\">Nap\u0119d prze\u0142\u0105czania jest uruchamiany przez kondensator, i r\u00f3wnoleg\u0142e pod\u0142\u0105czanie do innych urz\u0105dze\u0144 wp\u0142ynie na warto\u015b\u0107 pojemno\u015bci kondensatora rozruchowego. Dlatego, nap\u0119d prze\u0142\u0105czania mo\u017ce korzysta\u0107 tylko jedno sterowanie, a nie r\u00f3wnolegle.<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td rowspan=\"2\" class=\"column-1\">Nap\u0119d mo\u017ce by\u0107 w\u0142\u0105czony lub wy\u0142\u0105czony<\/td><td class=\"column-2\">1. Nieprawid\u0142owe okablowanie<\/td><td class=\"column-3\">1. U\u017cyj mechaniczny prze\u0142\u0105cznik do pomiaru funkcji nap\u0119du. Je\u015bli nap\u0119d dzia\u0142a poprawnie, nale\u017cy sprawdzi\u0107, czy logika wyj\u015bcia systemu zarz\u0105dzania oczekiwania?<br \/>\n2. Sprawd\u017a poprawno\u015b\u0107 pod\u0142\u0105czenia zgodnie ze schematem pod\u0142\u0105czenia nap\u0119du?<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-2\">2. Nieprawid\u0142owa konfiguracja w pe\u0142ni w\u0142\u0105czonego \/ca\u0142kowicie wy\u0142\u0105czonego cam<\/td><td class=\"column-3\">link<a href=\"\/pl_pl\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Jak ustawi\u0107 zaw\u00f3r elektryczny z prze\u0142\u0105cznikiem&#034;<\/a>Poprawnie ustaw po\u0142o\u017cenie krzywki.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td rowspan=\"3\" class=\"column-1\">Nap\u0119d zatrzymuje si\u0119 w po\u0142owie skoku<\/td><td class=\"column-2\">1. Zast\u00f3j zaworu<\/td><td class=\"column-3\">Sprawd\u017a, czy zaw\u00f3r si\u0119 zaci\u0105\u0142, napraw zatarcie i spr\u00f3buj ponownie po ostygni\u0119ciu nap\u0119du za pomoc\u0105 ochrony przed przeci\u0105\u017ceniem.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">2. Ewentualne cz\u0105stki sta\u0142e w cieczy \u015brodowisku prowadzi\u0107 do stagnacji zaworu.<\/td><td class=\"column-3\">Sprawd\u017a, czy nie ma cia\u0142 sta\u0142ych, uwi\u0119zionych w \u015brodowisku p\u0142yn\u00f3w, napraw zatarcie zaworu i spr\u00f3buj ponownie po ostygni\u0119ciu nap\u0119du za pomoc\u0105 ochrony przed przeci\u0105\u017ceniem.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">3. Nieprawid\u0142owa instalacja jest ca\u0142kowicie w\u0142\u0105czonego \/ ca\u0142kowicie wy\u0142\u0105czonego stopera<\/td><td class=\"column-3\">link<a href=\"\/pl_pl\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Jak ustawi\u0107 zaw\u00f3r elektryczny z prze\u0142\u0105cznikiem&#034;<\/a>Ustaw blokad\u0119 w prawid\u0142owej pozycji.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Za pomoc\u0105 uchwytu, nap\u0119d nie mo\u017cna obr\u00f3ci\u0107<\/td><td class=\"column-2\">1. Ewentualne cz\u0105stki sta\u0142e w cieczy \u015brodowisku prowadz\u0105 do zaci\u0119cie zaworu.<\/td><td class=\"column-3\">Sprawd\u017a, czy nie ma cia\u0142 sta\u0142ych, uwi\u0119zionych w \u015brodowisku p\u0142yn\u00f3w, napraw zatarcie zaworu i spr\u00f3buj ponownie po ostygni\u0119ciu nap\u0119du za pomoc\u0105 ochrony przed przeci\u0105\u017ceniem.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. Zaw\u00f3r zatrzymany<\/td><td class=\"column-3\">Sprawd\u017a, czy zaw\u00f3r si\u0119 zaci\u0105\u0142, napraw zatarcie i spr\u00f3buj ponownie po ostygni\u0119ciu nap\u0119du za pomoc\u0105 ochrony przed przeci\u0105\u017ceniem.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. Uszkodzony mechanizm zwalniania nap\u0119du.<\/td><td class=\"column-3\">Zdj\u0105\u0107 si\u0142ownik z zaworu i obr\u00f3ci\u0107 pokr\u0119t\u0142o. Je\u015bli nie mo\u017cna go obr\u00f3ci\u0107, nale\u017cy wymieni\u0107 go na nowy nap\u0119d.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Sygna\u0142 zwrotny po\u0142o\u017cenia bez sygna\u0142u wyj\u015bciowego<\/td><td class=\"column-2\">1. Nieprawid\u0142owe okablowanie wy\u0142\u0105cznika<\/td><td class=\"column-3\">Sprawd\u017a poprawno\u015b\u0107 pod\u0142\u0105czenia zgodnie ze schematem pod\u0142\u0105czenia nap\u0119du?<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. Nieprawid\u0142owa konfiguracja w pe\u0142ni w\u0142\u0105czonego \/ca\u0142kowicie wy\u0142\u0105czonego cam<\/td><td class=\"column-3\">link<a href=\"\/pl_pl\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Jak ustawi\u0107 zaw\u00f3r elektryczny z prze\u0142\u0105cznikiem&#034;<\/a>Poprawnie ustaw po\u0142o\u017cenie krzywki.<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. Przeci\u0105\u017cenie pr\u0105dowe prowadzi do uszkodzenia prze\u0142\u0105cznika sygna\u0142u sprz\u0119\u017cenia zwrotnego po\u0142o\u017cenia.<\/td><td class=\"column-3\">1. link<a href=\"\/pl_pl\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Jak ustawi\u0107 zaw\u00f3r elektryczny z prze\u0142\u0105cznikiem&#034;<\/a>Sprawd\u017a , \u015bciska czy ca\u0142kowicie w\u0142\u0105czony \/ ca\u0142kowicie wy\u0142\u0105czony cam prze\u0142\u0105cznik sprz\u0119\u017cenia zwrotnego po\u0142o\u017cenia?<br \/>\n2. Czy w\u0142\u0105czony jest obw\u00f3d sprz\u0119\u017cenia zwrotnego po\u0142o\u017cenia przy pomiarze?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-31 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61551f6 elementor-widget elementor-widget-image\" data-id=\"61551f6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Actuators\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp 696w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-300x259.webp 300w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-14x12.webp 14w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80d621f elementor-widget elementor-widget-heading\" data-id=\"80d621f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Prosz\u0119 sprawdzi\u0107, czy spe\u0142niaj\u0105 warunki stosowania wymog\u00f3w w parametrach.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c66d29 elementor-widget elementor-widget-text-editor\" data-id=\"4c66d29\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 Nap\u0119d elektryczny mo\u017ce ulec uszkodzeniu z powodu niew\u0142a\u015bciwego u\u017cytkowania lub przy z\u0142ych warunkach stosowania. Po spe\u0142nieniu warunk\u00f3w, okre\u015blonych w specyfikacji produktu, b\u0119dzie zapewniona d\u0142uga bezawaryjna praca nap\u0119du.<\/p><ul><li><strong>Napi\u0119cie\uff1a<\/strong>Napi\u0119cie zasilania powinno mie\u015bci\u0107 si\u0119 w zakresie znamionowych napi\u0119\u0107 roboczych nap\u0119du. Przepi\u0119cie lub obni\u017cone napi\u0119cie mo\u017ce doprowadzi\u0107 do skr\u00f3cenia \u017cywotno\u015bci nap\u0119du.<\/li><li><span style=\"font-weight: bold;\">Pr\u0105d zasilania\uff1a<\/span>Poniewa\u017c pr\u0105d rozruchowy silnika jest znacznie wi\u0119ksza ni\u017c pr\u0105d znamionowy. Dla zapewnienia bezpiecznej pracy nap\u0119du, nale\u017cy korzysta\u0107 ze \u017ar\u00f3d\u0142a zasilania o mocy ponad 3 razy wi\u0119kszej od pr\u0105du znamionowego nap\u0119du.<\/li><li><strong>temperatura\uff1a<\/strong>Upewnij si\u0119, \u017ce nap\u0119d dzia\u0142a w ramach nominalnego zakresu temperatur pracy. Korzystanie z nap\u0119du w warunkach przekraczaj\u0105cych nominalny zakres temperatur pracy, mo\u017ce prowadzi\u0107 do pogorszenia pracy nap\u0119du lub skr\u00f3cenia \u017cywotno\u015bci i, ostatecznie, do wyj\u015bcia nap\u0119du obrotowego.<\/li><li><strong>\u015arodowisko\uff1a<\/strong>Nap\u0119d typu prze\u0142\u0105cznika DCL ma stopie\u0144 ochrony przed warunkami atmosferycznymi IP67. Zwykle nadaje si\u0119 do zastosowa\u0144 wewn\u0119trznych i zewn\u0119trznych. Zapewnia pewien stopie\u0144 ochrony przed deszczem i plamami. Ochrona nap\u0119du od deszczu, \u015bniegu, lodu i promieniowania uv (\u015bwiat\u0142o s\u0142oneczne) zazwyczaj przed\u0142u\u017ca \u017cywotno\u015b\u0107 produktu. Bardzo agresywne \u015brodowisko mog\u0105 doprowadzi\u0107 do przedwczesnego uszkodzenia sprz\u0119tu elektronicznego. Nie nale\u017cy u\u017cywa\u0107 \u043d\u0435\u0432\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u044b\u0435 nap\u0119dy serii w \u0432\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u043e\u0439 \u015brodowisku.<\/li><li><strong>Wsp\u00f3\u0142czynnik ci\u0105g\u0142o\u015bci w\u0142\u0105czy\u0107\uff1a<\/strong>Wsp\u00f3\u0142czynnik ci\u0105g\u0142o\u015bci w\u0142\u0105czania nap\u0119du prze\u0142\u0105czania dc wynosi 70% (pracuje 42 sekundy na minut\u0119 i musi by\u0107 wy\u0142\u0105czony na 18 sekund). Ponad 70% czasu ci\u0105g\u0142ego w\u0142\u0105czania doprowadzi do tego, \u017ce silnik przejdzie w tryb ochrony przed przegrzaniem.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdce1cd elementor-widget elementor-widget-heading\" data-id=\"cdce1cd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Sprawd\u017a poprawno\u015b\u0107 pod\u0142\u0105czenia nap\u0119du<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c4bef91 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c4bef91\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ec2666c\" data-id=\"ec2666c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a9dfe7 elementor-widget elementor-widget-heading\" data-id=\"7a9dfe7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ A: Z prze\u0142\u0105cznikiem po\u0142o\u017cenia kra\u0144cowego (aktywny kontakt)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d609f95 elementor-widget elementor-widget-image\" data-id=\"d609f95\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a-14x12.webp 14w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6bbe9b8 elementor-widget elementor-widget-text-editor\" data-id=\"6bbe9b8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Operacje na &#034;w\u0142.&#034; i &#034;wy\u0142.&#034; s\u0105 realizowane przez schemat prze\u0142\u0105czania, i pojawi si\u0119 zestaw w pe\u0142ni aktywne i ca\u0142kowicie wy\u0142\u0105czonych aktywnych alarm\u00f3w.<\/p><p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br \/>1. Zacisk 1 jest pod\u0142\u0105czony do linii \u015brodkowej \u017ar\u00f3d\u0142a zasilania\uff1b<br \/>2. Kiedy fazowe linii zasilania i zacisk 2 w\u0142\u0105czone, to jest w trybie &#034;wy\u0142.&#034;.\uff1b<br \/>3. Kiedy fazowe linii zasilania i zacisk 3 w\u0142\u0105czone, to jest w trybie &#034;all inclusive&#034;.\uff1b<br \/>4. Kiedy fazowe linii zasilania i zacisk 2 pod\u0142\u0105czone i jest wykonywana operacja &#034;wy\u0142.&#034;, \u015bwieci si\u0119 wska\u017anik &#034;sygna\u0142 ca\u0142kowitego wy\u0142\u0105czania&#034;, pod\u0142\u0105czony do zacisku 4.\uff1b<br \/>5. Kiedy fazowe linii zasilania i zacisk 3 s\u0105 pod\u0142\u0105czone i jest wykonywana operacja &#034;w\u0142.&#034;, \u015bwieci si\u0119 wska\u017anik &#034;sygna\u0142 pe\u0142nej \u0440\u0430\u0437\u043e\u043c\u043a\u043d\u0443\u0442\u043e\u0433\u043e po\u0142\u0105czenia&#034;, pod\u0142\u0105czony do zacisku 5.\uff1b<br \/>6. Zacisk 7 przewody uziemienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-920f58e\" data-id=\"920f58e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-69964db elementor-widget elementor-widget-heading\" data-id=\"69964db\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ B: Z prze\u0142\u0105cznikiem po\u0142o\u017cenia po\u015bredniego (pasywny kontakt)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85c2186 elementor-widget elementor-widget-image\" data-id=\"85c2186\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a9717e elementor-widget elementor-widget-text-editor\" data-id=\"1a9717e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Operacje na &#034;w\u0142.&#034; i &#034;wy\u0142.&#034; s\u0105 realizowane przez architektur\u0119 schemat, i pojawi si\u0119 zestaw w pe\u0142ni aktywne i ca\u0142kowicie wy\u0142\u0105czonych pasywnych sygna\u0142\u00f3w.<\/p><p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br \/>1. Zacisk 1 jest pod\u0142\u0105czony do linii \u015brodkowej \u017ar\u00f3d\u0142a zasilania\uff1b<br \/>2. Kiedy fazowe linii zasilania i zacisk 2 w\u0142\u0105czone, to jest w trybie &#034;wy\u0142.&#034;.\uff1b<br \/>3. Kiedy fazowe linii zasilania i zacisk 3 w\u0142\u0105czone, to jest w trybie &#034;all inclusive&#034;.\uff1b<br \/>4. Zacisk 4 jest wsp\u00f3lnym zaciskiem pasywnych kontakt\u00f3w\uff1b<br \/>5. Gdy wykonywana jest operacja &#034;otwarta&#034;, zacisk 5 daje sygna\u0142 &#034;ca\u0142kowicie otwarty&#034;.;<br \/>6. Gdy przycisk &#034;wy\u0142.&#034; jest zainstalowany, terminal daje &#034;sygna\u0142 ca\u0142kowitego wy\u0142.&#034;. \uff1b<br \/>7. Zacisk 7 przewody uziemienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3ebb697 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3ebb697\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3fdff56\" data-id=\"3fdff56\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e449214 elementor-widget elementor-widget-heading\" data-id=\"e449214\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ C: z potencjometrem o mocy 1 kw (500 OHM)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4b3915 elementor-widget elementor-widget-image\" data-id=\"c4b3915\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"380\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-c.webp\" class=\"attachment-full size-full wp-image-4856\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668C\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-c.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-c-13x12.webp 13w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5aa67a elementor-widget elementor-widget-text-editor\" data-id=\"f5aa67a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Operacje na &#034;w\u0142.&#034; i &#034;wy\u0142.&#034; s\u0105 realizowane przez architektur\u0119 schemat, i pojawia si\u0119 sygna\u0142 oporu, odpowiedni stan wyzwolenia.<\/p><p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br \/>1. Zacisk 1 jest pod\u0142\u0105czony do linii \u015brodkowej \u017ar\u00f3d\u0142a zasilania\uff1b<br \/>2. Kiedy fazowe linii zasilania i zacisk 2 w\u0142\u0105czone, to jest w trybie &#034;wy\u0142.&#034;.\uff1b<br \/>3. Kiedy fazowe linii zasilania i zacisk 3 w\u0142\u0105czone, to jest w trybie &#034;all inclusive&#034;.\uff1b<br \/>4. Zacisk 4 jest dolnym ko\u0144cem potencjometru. Po w\u0142\u0105czeniu warto\u015b\u0107 rezystancji mi\u0119dzy zaciskami 4 i 5 zwi\u0119ksza si\u0119 w miar\u0119 wzrostu stopnia wyzwolenia.\uff1b<br \/>5. Zacisk 5 jest strza\u0142k\u0105 potencjometru\uff1b<br \/>6. Zacisk 6 jest g\u00f3rn\u0105 cz\u0119\u015bci\u0105 potencjometru. Kiedy jest w\u0142\u0105czone, warto\u015b\u0107 rezystancji mi\u0119dzy zaciskami 6 i 5 zmniejsza si\u0119 w miar\u0119 zwi\u0119kszania wyzwolenia.\uff1b<br \/>7. Zacisk 7 przewody uziemienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ad7634c\" data-id=\"ad7634c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4368662 elementor-widget elementor-widget-heading\" data-id=\"4368662\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ D: z potencjometrem i pasywny prze\u0142\u0105cznik po\u0142o\u017cenia kontaktu<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1941c4 elementor-widget elementor-widget-image\" data-id=\"c1941c4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"437\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-d.webp\" class=\"attachment-full size-full wp-image-4859\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668D\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-d.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-d-11x12.webp 11w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4aa2119 elementor-widget elementor-widget-text-editor\" data-id=\"4aa2119\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Operacje na &#034;w\u0142.&#034; i &#034;wy\u0142.&#034; s\u0105 realizowane przez schemat prze\u0142\u0105czania, i pojawia si\u0119 sygna\u0142 oporu, odpowiedni stan wyzwolenia, a jednocze\u015bnie pojawi si\u0119 zestaw w pe\u0142ni aktywne i ca\u0142kowicie wy\u0142\u0105czonych pasywnych sygna\u0142\u00f3w.<\/p><p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br \/>1. Zacisk 1 jest pod\u0142\u0105czony do linii \u015brodkowej \u017ar\u00f3d\u0142a zasilania\uff1b<br \/>2. Kiedy fazowe linii zasilania i zacisk 2 w\u0142\u0105czone, to jest w trybie &#034;wy\u0142.&#034;.\uff1b<br \/>3. Kiedy fazowe linii zasilania i zacisk 3 w\u0142\u0105czone, to jest w trybie &#034;all inclusive&#034;.\uff1b<br \/>4. Zacisk 4 jest wsp\u00f3lnym zaciskiem pasywnych kontakt\u00f3w\uff1b<br \/>5. Gdy wykonywana jest operacja &#034;otwarta&#034;, zacisk 5 daje sygna\u0142 &#034;ca\u0142kowicie otwarty&#034;.\uff1b<br \/>6. Gdy przycisk &#034;wy\u0142.&#034; jest zainstalowany, terminal wysy\u0142a sygna\u0142 &#034;pe\u0142nego&#034; wy\u0142.&#034;.;<br \/>7. Zacisk 7 jest dolnym ko\u0144cem potencjometru. Przy w\u0142\u0105czonym trybie &#034;otwarcie&#034; warto\u015b\u0107 rezystancji mi\u0119dzy zaciskami 7 i 8 zwi\u0119ksza si\u0119 w miar\u0119 wzrostu stopnia wyzwolenia.\uff1b<br \/>8. Zacisk 8 jest strza\u0142k\u0105 potencjometru\uff1b<br \/>9. Zacisk 9 jest g\u00f3rn\u0105 cz\u0119\u015bci\u0105 lokalizatora. Przy w\u0142\u0105czonym trybie &#034;otwarcie&#034; warto\u015b\u0107 rezystancji mi\u0119dzy zaciskami 9 i 8 zmniejsza si\u0119 w miar\u0119 zwi\u0119kszania wyzwolenia.\uff1b<br \/>10. Zacisk 12 przewody uziemienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-986a256 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"986a256\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1b4006e\" data-id=\"1b4006e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-44c989d elementor-widget elementor-widget-heading\" data-id=\"44c989d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ F: z czujnikiem po\u0142o\u017cenia<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04d92ee elementor-widget elementor-widget-image\" data-id=\"04d92ee\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"316\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-f.webp\" class=\"attachment-full size-full wp-image-4855\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668F\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-f.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-f-15x12.webp 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2249dac elementor-widget elementor-widget-text-editor\" data-id=\"2249dac\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Operacje na &#034;w\u0142.&#034; i &#034;wy\u0142.&#034; s\u0105 realizowane przez schemat prze\u0142\u0105czania, i pojawi si\u0119 zestaw w pe\u0142ni aktywne i ca\u0142kowicie wy\u0142\u0105czonych aktywnych alarm\u00f3w.<\/p>\n<p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br>1. Litera &#034;N&#034; na wej\u015bciu &#034;\u017ar\u00f3d\u0142a ZASILANIA&#034; jest pod\u0142\u0105czony do linii \u015brodkowej, a litera &#034;L&#034; jest pod\u0142\u0105czony do fazy linii.;<br>2. Gdy fazy linia &#034;L&#034; na wej\u015bciu &#034;\u017ar\u00f3d\u0142a ZASILANIA&#034; pod\u0142\u0105czona do &#034;wy\u0142.&#034;, ona dzia\u0142a w kierunku &#034;wy\u0142.&#034;, a gdy jest ona pod\u0142\u0105czona do &#034;w\u0142.&#034;, ona dzia\u0142a w kierunku &#034;w\u0142.&#034;.\uff1b<br>3. Zacisk wyj\u015bciowy sygna\u0142&#034; jest pod\u0142\u0105czony do ujemnej elektrody amperomierz pr\u0105du sta\u0142ego, a zacisk &#034;+&#034; jest pod\u0142\u0105czony do elektrody dodatniej i amperomierza pr\u0105du sta\u0142ego.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fe3e435\" data-id=\"fe3e435\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-669c582 elementor-widget elementor-widget-heading\" data-id=\"669c582\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ G: Schemat sterowania pr\u0105dem sta\u0142ym z pasywnym wy\u0142\u0105cznikiem stykowym<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35d9b4b elementor-widget elementor-widget-image\" data-id=\"35d9b4b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34dba4c elementor-widget elementor-widget-text-editor\" data-id=\"34dba4c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zgodnie z jednokierunkowa przewodno\u015bci diody, poprzez prze\u0142\u0105czania pozytywnego i negatywnego elektrod \u017ar\u00f3d\u0142a pr\u0105du sta\u0142ego realizowane s\u0105 operacje &#034;w\u0142.&#034; i &#034;wy\u0142.&#034; i pojawi si\u0119 zestaw w pe\u0142ni aktywne i ca\u0142kowicie wy\u0142\u0105czonych pasywnych sygna\u0142\u00f3w.<\/p><p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br \/>1. Zacisk 1 jest pod\u0142\u0105czony do elektrody dodatniej \u017ar\u00f3d\u0142a zasilania a zacisk 2 jest w trybie &#034;off&#034;, gdy jest ona pod\u0142\u0105czona do ujemnej elektrody \u017ar\u00f3d\u0142a zasilania; zacisk 2 jest pod\u0142\u0105czony do elektrody dodatniej \u017ar\u00f3d\u0142a zasilania a zacisk 1 znajduje si\u0119 w trybie &#034;all inclusive&#034;, gdy jest ona pod\u0142\u0105czona do ujemnej elektrody \u017ar\u00f3d\u0142a zasilania.\uff1b<br \/>2. Zacisk 3 jest wsp\u00f3lnym zaciskiem pasywnych kontakt\u00f3w\uff1b<br \/>3. Gdy wykonywana jest operacja &#034;otwarta&#034;, terminal naprawd\u0119 daje sygna\u0142 &#034;ca\u0142kowicie otwarty&#034;.;<br \/>4. Gdy przycisk &#034;wy\u0142.&#034; jest zainstalowany, zacisk 5 daje &#034;sygna\u0142 ca\u0142kowitego wy\u0142.&#034;.;<br \/>5. Zacisk 7 przewody uziemienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-e3d71b9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e3d71b9\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-98695b9\" data-id=\"98695b9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-30aff6d elementor-widget elementor-widget-heading\" data-id=\"30aff6d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Typ H: Tr\u00f3jfazowa schemat sterowania pr\u0105dem przemiennym z pasywnym wy\u0142\u0105cznikiem stykowym<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4e9fe9 elementor-widget elementor-widget-image\" data-id=\"b4e9fe9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"412\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-h.webp\" class=\"attachment-full size-full wp-image-4854\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668H\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-h.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-h-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb8b4e9 elementor-widget elementor-widget-text-editor\" data-id=\"cb8b4e9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Za pomoc\u0105 zewn\u0119trznej \u0438\u043d\u0432\u0435\u0440\u0442\u0438\u0440\u0443\u044e\u0449\u0435\u0439 schematu silnik obraca si\u0119 do przodu i do ty\u0142u, aby wykonywa\u0107 operacje &#034;w\u0142\u0105czony&#034; i &#034;wy\u0142\u0105czony&#034; i wyda\u0107 zestaw pasywnych sygna\u0142\u00f3w &#034;w pe\u0142ni w\u0142\u0105czone&#034; i &#034;ca\u0142kowicie wy\u0142\u0105czone&#034;.<\/p><p><strong>Instrukcje pod\u0142\u0105czania\uff1a<\/strong><br \/>1. Zaciski 1, 2 i 3 s\u0105 pod\u0142\u0105czone do tr\u00f3jfazowego \u017ar\u00f3d\u0142a pr\u0105du przemiennego i silnika w\u0142\u0105cza si\u0119 do przodu i do ty\u0142u przez zewn\u0119trzn\u0105 \u0438\u043d\u0432\u0435\u0440\u0442\u0438\u0440\u0443\u044e\u0449\u0443\u044e \u0142a\u0144cuch.\uff1b<br \/>2. Zacisk 4 jest wsp\u00f3lnym zaciskiem zewn\u0119trznego obwodu sterowania\uff1b<br \/>3. Zacisk 5 &#034;wy\u0142\u0105czona&#034; do sterowania prac\u0105\uff1b<br \/>4. Terminal 6 znajduje si\u0119 w trybie &#034;all inclusive&#034; sterowania prac\u0105\uff1b<br \/>5. Zacisk 7 jest wsp\u00f3lnym zaciskiem pasywnych kontakt\u00f3w\uff1b<br \/>6. Gdy wykonywana jest operacja &#034;otwarta&#034;, terminal wysy\u0142a sygna\u0142 &#034;ca\u0142kowicie otwarty&#034;.;<br \/>7. Gdy przycisk &#034;wy\u0142.&#034; jest zainstalowany, zacisk 9 daje &#034;sygna\u0142 ca\u0142kowitego wy\u0142.&#034;.\uff1b<br \/>8. Zacisk 12 przewody uziemienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c0158b3\" data-id=\"c0158b3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u9632\u7206\u7cfb\u5217\/\u666e\u901a\u7cfb\u5217\/\u5feb\u5f00\u7cfb\u5217\u7684\u5f00\u5173\u578b\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a \u666e\u901a\u7cfb\u5217\uff1aDCL-05\/DCL-10 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6913,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[387,378,44,34,42,41],"class_list":["post-6032","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-trouble-shooting-guide","tag-on-off-actuator","tag-fast-move-actuator","tag-actuator","tag-general-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/posts\/6032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/comments?post=6032"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/posts\/6032\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/media\/6913"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/media?parent=6032"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/categories?post=6032"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/pl_pl\/wp-json\/wp\/v2\/tags?post=6032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}