{"id":6032,"date":"2023-08-03T20:13:29","date_gmt":"2023-08-03T12:13:29","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6032"},"modified":"2025-04-18T11:35:15","modified_gmt":"2025-04-18T03:35:15","slug":"switch-actuator","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/it_it\/support\/mr-actuator\/switch-actuator","title":{"rendered":"I guasti pi\u00f9 comuni e troubleshooting di switch-tipo di attuatori"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6032\" class=\"elementor elementor-6032\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fe621b5 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"fe621b5\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a1fea6d\" data-id=\"a1fea6d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-49fc89d elementor-widget elementor-widget-text-editor\" data-id=\"49fc89d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Questa procedura guidata \u00e8 adatto per switch tipo di attuatori di DCL antideflagranti serie\/serie ordinarie\/apertura rapida serie. I modelli sono come segue: per<\/p><ul><li>Ordinarie serie: DCL-05\/DCL-10\/DCL-20\/DCL-40\/DCL-60\/DCL-100\/DL-160\/DCL-250<\/li><li>A prova di esplosione serie: DCL-Ex05\/DCL-Ex10\/DCL-Ex20\/DCL-Ex40\/DCL-Ex60<\/li><li>Quick open serie: DCL-K05\/DCL-K10\/DCL-K20\/DCL-K40\/DCL-K100<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e165a97 elementor-widget elementor-widget-heading\" data-id=\"e165a97\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. I guasti pi\u00f9 comuni e metodi di risoluzione dei problemi.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e767e9 elementor-widget elementor-widget-shortcode\" data-id=\"0e767e9\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-31\" class=\"tablepress tablepress-id-31 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">colpa<\/th><th class=\"column-2\">Possibile causa<\/th><th class=\"column-3\">Metodo di esclusione<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\">L&#039;attuatore non si accende o spegne quando viene avviato per la prima<\/td><td class=\"column-2\">1. Un cablaggio non corretto<\/td><td class=\"column-3\">Controllare se il cablaggio \u00e8 corretto secondo lo schema elettrico dell&#039;attuatore?<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. Alimentazione non corretta<\/td><td class=\"column-3\">Verificare che la tensione di uscita dell&#039;alimentatore \u00e8 di \u00b110% della tensione nominale dell&#039;attuatore, e la corrente di uscita \u00e8 di 3 volte la corrente nominale dell&#039;attuatore.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. Anormale interruttore di comando o di controllo a rel\u00e8<\/td><td class=\"column-3\">Utilizzare un multimetro per misurare la tensione in ingresso al terminale di controllo dell&#039;attuatore switch per confermare se esso soddisfa le aspettative?<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. Sistema di controllo di corrispondenza problema<\/td><td class=\"column-3\">Utilizzare un interruttore meccanico per misurare il funzionamento dell&#039;attuatore. Se l&#039;attuatore \u00e8 in esecuzione normalmente, controllare se la logica di uscita del sistema di controllo soddisfa le aspettative?<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. Pi\u00f9 attuatori e comandi in parallelo con altre apparecchiature<\/td><td class=\"column-3\">L&#039;attuatore viene avviato tramite il condensatore di avviamento e di messa in parallelo con altre apparecchiature, avr\u00e0 un impatto sul valore di capacit\u00e0 del condensatore di avviamento. Pertanto, l&#039;attuatore pu\u00f2 utilizzare solo un singolo controllo, non in parallelo.<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td rowspan=\"2\" class=\"column-1\">L&#039;attuatore pu\u00f2 essere acceso o spento<\/td><td class=\"column-2\">1. Un cablaggio non corretto<\/td><td class=\"column-3\">1. Utilizzare un interruttore meccanico per misurare il funzionamento dell&#039;attuatore. Se l&#039;attuatore \u00e8 in esecuzione normalmente, controllare se la logica di uscita del sistema di controllo soddisfa le aspettative?<br \/>\n2. Controllare se il cablaggio \u00e8 corretto secondo lo schema elettrico dell&#039;attuatore?<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-2\">2. Un&#039;errata impostazione completamente on\/fullyoff cam<\/td><td class=\"column-3\">riferimento<a href=\"\/it_it\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Come impostare un interruttore di tipo Elettrico valvola&#034;<\/a>Impostare la posizione della camma correttamente.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td rowspan=\"3\" class=\"column-1\">L&#039;attuatore si ferma a met\u00e0 del viaggio<\/td><td class=\"column-2\">1. Valvola di stagnazione<\/td><td class=\"column-3\">Controllare se la valvola \u00e8 bloccata, eliminare bloccato, e provare di nuovo dopo l&#039;attuatore \u00e8 raffreddato da una protezione da sovraccarico.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">2. Potenziale di solidi in mezzo fluido causare la valvola a ristagnare.<\/td><td class=\"column-3\">Verificare se ci sono solidi bloccato nel mezzo fluido, eliminare la valvola bloccata, e provare di nuovo dopo l&#039;attuatore \u00e8 raffreddato da una protezione da sovraccarico.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">3. Un&#039;errata impostazione completamente on\/completamente off tappo<\/td><td class=\"column-3\">riferimento<a href=\"\/it_it\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Come impostare un interruttore di tipo Elettrico valvola&#034;<\/a>Impostare il tappo in posizione corretta.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Utilizzando la maniglia, l&#039;azionatore pu\u00f2 essere ruotato<\/td><td class=\"column-2\">1. Potenziale di solidi in mezzo fluido causare la valvola per ottenere bloccato.<\/td><td class=\"column-3\">Verificare se ci sono solidi bloccato nel mezzo fluido, eliminare la valvola bloccata, e provare di nuovo dopo l&#039;attuatore \u00e8 raffreddato da una protezione da sovraccarico.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. Valvola bloccata<\/td><td class=\"column-3\">Controllare se la valvola \u00e8 bloccata, eliminare bloccato, e provare di nuovo dopo l&#039;attuatore \u00e8 raffreddato da una protezione da sovraccarico.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. L&#039;attuatore decelerazione meccanismo \u00e8 danneggiato.<\/td><td class=\"column-3\">Rimuovere l&#039;attuatore dalla valvola e ruotare la maniglia. Se non pu\u00f2 essere ruotato, sostituirlo con un nuovo attuatore.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Posizione del segnale di feedback senza uscita<\/td><td class=\"column-2\">1. Non corretto cablaggio dell&#039;interruttore<\/td><td class=\"column-3\">Controllare se il cablaggio \u00e8 corretto secondo lo schema elettrico dell&#039;attuatore?<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. Un&#039;errata impostazione completamente on\/fullyoff cam<\/td><td class=\"column-3\">riferimento<a href=\"\/it_it\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Come impostare un interruttore di tipo Elettrico valvola&#034;<\/a>Impostare la posizione della camma correttamente.<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. Sovracorrente danneggia il feedback di posizione dell&#039;interruttore del segnale.<\/td><td class=\"column-3\">1. riferimento<a href=\"\/it_it\/faq\/actuator\/set-up-dcl-valve\/\">&#034;Come impostare un interruttore di tipo Elettrico valvola&#034;<\/a>Verificare se il completamente on\/fullyoff cam compatta il feedback di posizione interruttore?<br \/>\n2. \u00c8 la posizione di misurazione ciclo di feedback acceso?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-31 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61551f6 elementor-widget elementor-widget-image\" data-id=\"61551f6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Actuators\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp 696w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-300x259.webp 300w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-14x12.webp 14w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80d621f elementor-widget elementor-widget-heading\" data-id=\"80d621f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Si prega di verificare se l&#039;applicazione di condizioni di soddisfare i requisiti dei parametri.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c66d29 elementor-widget elementor-widget-text-editor\" data-id=\"4c66d29\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 L&#039;attuatore elettrico potrebbe non riuscire a causa di un uso improprio o errato condizioni di applicazione. Sotto l&#039;applicazione di condizioni definite nel disciplinare, a lungo termine il funzionamento dell&#039;attuatore sar\u00e0 assicurato.<\/p><ul><li><strong>Alimentazione di tensione:<\/strong>La tensione di alimentazione deve essere compresa nominale gamma di tensione di funzionamento dell&#039;attuatore. Protezione da sovratensione o sottotensione pu\u00f2 causare la vita dell&#039;attuatore essere ridotta.<\/li><li><span style=\"font-weight: bold;\">Alimentazione di corrente:<\/span>Dal momento che la corrente di avviamento del motore \u00e8 molto pi\u00f9 grande della corrente nominale. Per garantire il buon funzionamento dell&#039;attuatore, si prega di utilizzare un alimentatore con una tensione di uscita capacit\u00e0 superiore a 3 volte la corrente nominale dell&#039;attuatore.<\/li><li><strong>temperature\uff1a<\/strong>Assicurarsi che l&#039;attuatore \u00e8 in funzione all&#039;interno nominale intervallo di temperatura di funzionamento. L&#039;uso dell&#039;attuatore in un ambiente che supera nominale intervallo di temperatura di funzionamento pu\u00f2 compromettere la funzione attuatore o riduzione del servizio di vita, e, infine, portare al fallimento dell&#039;attuatore.<\/li><li><strong>ambiente\uff1a<\/strong>Il DCL tipo di interruttore attuatore \u00e8 dotato di un IP67 impermeabile rating. Generalmente adatto per applicazioni in interni ed esterni. Fornire un certo grado di pioggia e di protezione contro gli spruzzi. Proteggere l&#039;attuatore dalla pioggia, la neve, il ghiaccio e la luce ultravioletta (luce del sole) di solito prolunga la vita del prodotto. Molto corrosivo pu\u00f2 causare il guasto prematuro di apparecchiature elettroniche. Non utilizzare-a prova di esplosione serie di attuatori in un&#039;esplosione, a prova di ambiente.<\/li><li><strong>Potenza-in continuit\u00e0 tasso di\uff1a<\/strong>Il power-on continuit\u00e0 tasso di DCL attuatore \u00e8 del 70% (corre per 42 secondi al minuto e deve essere spento per 18 secondi). Oltre il 70% della tensione di alimentazione di continuit\u00e0 tasso far\u00e0 s\u00ec che il motore di inserire la protezione contro il surriscaldamento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdce1cd elementor-widget elementor-widget-heading\" data-id=\"cdce1cd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Controllare se il cablaggio dell&#039;attuatore \u00e8 corretto<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c4bef91 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c4bef91\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ec2666c\" data-id=\"ec2666c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a9dfe7 elementor-widget elementor-widget-heading\" data-id=\"7a9dfe7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo A: Con il limite di interruttore di posizione (contatto attivo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d609f95 elementor-widget elementor-widget-image\" data-id=\"d609f95\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a-14x12.webp 14w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6bbe9b8 elementor-widget elementor-widget-text-editor\" data-id=\"6bbe9b8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cOn\u201d e \u201coff\u201d operazioni sono realizzati attraverso la commutazione di circuito, e una serie di pienamente e completamente off attiva segnali di uscita.<\/p><p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br \/>1. Il Terminal 1 \u00e8 collegato al centro della linea di alimentazione\uff1b<br \/>2. Quando l&#039;alimentazione linea di fase e il terminal 2 sono accesi, \u00e8 \u201coff\u201d operazione.\uff1b<br \/>3. Quando l&#039;alimentazione linea di fase e il terminal 3 sono accesi, ma \u00e8 \u201csu\u201d operazione.\uff1b<br \/>4. Quando l&#039;alimentazione linea di fase e il terminal 2 sono collegati e il \u201cfuori\u201d, l&#039;operazione \u00e8 a posto, il \u201cfull off del segnale\u201c indicatore collegato al terminal 4.\uff1b<br \/>5. Quando l&#039;alimentazione della tensione di fase e di linea terminal 3 sono collegati e \u201con\u201d l&#039;operazione \u00e8 a posto, il \u201ctutto aperto\u201c segnale indicatore collegato al terminal 5 \u00e8.\uff1b<br \/>6. Terminale 7 filo di terra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-920f58e\" data-id=\"920f58e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-69964db elementor-widget elementor-widget-heading\" data-id=\"69964db\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo B: Con interruttore posizione intermedia (contatto passivo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85c2186 elementor-widget elementor-widget-image\" data-id=\"85c2186\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a9717e elementor-widget elementor-widget-text-editor\" data-id=\"1a9717e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cOn\u201d e \u201coff\u201d operazioni sono realizzati attraverso la commutazione di circuito, e una serie di pienamente e completamente passivo segnali di uscita.<\/p><p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br \/>1. Il Terminal 1 \u00e8 collegato al centro della linea di alimentazione\uff1b<br \/>2. Quando l&#039;alimentazione linea di fase e il terminal 2 sono accesi, \u00e8 \u201coff\u201d operazione.\uff1b<br \/>3. Quando l&#039;alimentazione linea di fase e il terminal 3 sono accesi, ma \u00e8 \u201csu\u201d operazione.\uff1b<br \/>4. Il Terminal 4 \u00e8 il terminale comune di passivo contatti\uff1b<br \/>5. Quando l&#039;operazione \u201copen\u201d \u00e8 a posto, il terminal 5 uscite a \u201caprire completamente il segnale\u201d.;<br \/>6. Quando \u201doff&#034;, il terminale compila una \u201cfull off del segnale\u201c. \uff1b<br \/>7. Terminale 7 filo di terra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3ebb697 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3ebb697\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3fdff56\" data-id=\"3fdff56\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e449214 elementor-widget elementor-widget-heading\" data-id=\"e449214\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo C: con 1KW (o 500 \u03a9) potenziometro<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4b3915 elementor-widget elementor-widget-image\" data-id=\"c4b3915\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"380\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-c.webp\" class=\"attachment-full size-full wp-image-4856\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668C\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-c.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-c-13x12.webp 13w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5aa67a elementor-widget elementor-widget-text-editor\" data-id=\"f5aa67a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cOn\u201d e \u201coff\u201d operazioni sono realizzati attraverso la commutazione di circuito e la resistenza del segnale corrispondente alla posizione di apertura \u00e8 uscita.<\/p><p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br \/>1. Il Terminal 1 \u00e8 collegato al centro della linea di alimentazione\uff1b<br \/>2. Quando l&#039;alimentazione linea di fase e il terminal 2 sono accesi, \u00e8 \u201coff\u201d operazione.\uff1b<br \/>3. Quando l&#039;alimentazione linea di fase e il terminal 3 sono accesi, ma \u00e8 \u201csu\u201d operazione.\uff1b<br \/>4. Il Terminal 4 \u00e8 la fascia bassa del potenziometro. Quando \u201ca\u201d \u00e8 in esecuzione, il valore di resistenza tra i morsetti 4 e 5 terminale aumenta il grado di apertura aumenta.\uff1b<br \/>5. Il Terminal 5 \u00e8 il potenziometro boom\uff1b<br \/>6. Terminale 6 \u00e8 il pi\u00f9 alto del potenziometro. Quando \u201ca\u201d \u00e8 in esecuzione, il valore di resistenza tra i morsetti 6 e il terminal 5 diminuisce l&#039;apertura aumenta.\uff1b<br \/>7. Terminale 7 filo di terra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ad7634c\" data-id=\"ad7634c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4368662 elementor-widget elementor-widget-heading\" data-id=\"4368662\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo D: con potenziometro e passivo contatto interruttore di posizione<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1941c4 elementor-widget elementor-widget-image\" data-id=\"c1941c4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"437\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-d.webp\" class=\"attachment-full size-full wp-image-4859\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668D\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-d.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-d-11x12.webp 11w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4aa2119 elementor-widget elementor-widget-text-editor\" data-id=\"4aa2119\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cOn\u201d e \u201coff\u201d operazioni sono realizzati attraverso la commutazione di circuito e la resistenza del segnale corrispondente alla posizione di apertura \u00e8 uscita, e una serie di pienamente e completamente passivo segnali in uscita allo stesso tempo.<\/p><p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br \/>1. Il Terminal 1 \u00e8 collegato al centro della linea di alimentazione\uff1b<br \/>2. Quando l&#039;alimentazione linea di fase e il terminal 2 sono accesi, \u00e8 \u201coff\u201d operazione.\uff1b<br \/>3. Quando l&#039;alimentazione linea di fase e il terminal 3 sono accesi, ma \u00e8 \u201csu\u201d operazione.\uff1b<br \/>4. Il Terminal 4 \u00e8 il terminale comune di passivo contatti\uff1b<br \/>5. Quando l&#039;operazione \u201copen\u201d \u00e8 a posto, il terminal 5 uscite a \u201caprire completamente il segnale\u201c.\uff1b<br \/>6. Quando \u201coff\u201d, il terminale invia un \u201cfull off del segnale\u201c.;<br \/>7. Terminale 7 \u00e8 la fascia bassa del potenziometro. Quando \u201capri\u201d \u00e8 in esecuzione, il valore di resistenza tra i morsetti 7 e terminal 8 aumenta il grado di apertura aumenta.\uff1b<br \/>8. Terminale 8 \u00e8 il potenziometro boom\uff1b<br \/>9. Morsetto 9 \u00e8 la fascia alta del localizzatore. Quando \u201capri\u201d \u00e8 in esecuzione, il valore di resistenza tra i morsetti 9 e il terminal 8 diminuisce l&#039;apertura aumenta.\uff1b<br \/>10. Morsetto 12 filo di terra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-986a256 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"986a256\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1b4006e\" data-id=\"1b4006e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-44c989d elementor-widget elementor-widget-heading\" data-id=\"44c989d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo F: con trasmettitore di posizione<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04d92ee elementor-widget elementor-widget-image\" data-id=\"04d92ee\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"316\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-f.webp\" class=\"attachment-full size-full wp-image-4855\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668F\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-f.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-f-15x12.webp 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2249dac elementor-widget elementor-widget-text-editor\" data-id=\"2249dac\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cOn\u201d e \u201coff\u201d operazioni sono realizzati attraverso la commutazione di circuito, e una serie di pienamente e completamente off attiva segnali di uscita.<\/p>\n<p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br>1. La \u201cN\u201d all&#039;ingresso di ALIMENTAZIONE \u00e8 collegato alla linea di mezzo, e la \u201cL\u201d \u00e8 collegato alla linea di fase.;<br>2. Quando la fase della linea \u201cL\u201d all&#039;ingresso del \u201cALIMENTAZIONE\u201d \u00e8 collegato a \u201coff\u201d, corre nella direzione di, e quando \u00e8 collegato a \u201con\u201d, viene eseguito con la direzione.\uff1b<br>3. Il \u201dsegnale di uscita\u201c terminale \u00e8 collegato all&#039;elettrodo negativo della DC amperometro e il terminale \u201d+&#034; \u00e8 collegato all&#039;elettrodo positivo della DC amperometro.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fe3e435\" data-id=\"fe3e435\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-669c582 elementor-widget elementor-widget-heading\" data-id=\"669c582\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo G: DC del circuito di controllo passivo interruttore di contatto<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35d9b4b elementor-widget elementor-widget-image\" data-id=\"35d9b4b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34dba4c elementor-widget elementor-widget-text-editor\" data-id=\"34dba4c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Secondo il unidirezionale conducibilit\u00e0 del diodo, dal pendolarismo gli elettrodi positivi e negativi dell&#039;alimentazione in corrente continua, \u201con\u201d e \u201coff\u201d le operazioni sono realizzate e completamente e completamente passivo segnali di uscita.<\/p><p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br \/>1. Il Terminal 1 \u00e8 collegato all&#039;elettrodo positivo dell&#039;alimentazione, e il terminal 2 \u00e8 \u201coff\u201d, l&#039;operazione quando \u00e8 collegato all&#039;elettrodo negativo dell&#039;alimentatore; il terminal 2 \u00e8 collegato all&#039;elettrodo positivo dell&#039;alimentazione, e il terminal 1 \u00e8 \u201con\u201d, l&#039;operazione quando \u00e8 collegato all&#039;elettrodo negativo dell&#039;alimentazione.\uff1b<br \/>2. Il Terminal 3 \u00e8 il terminale comune di passivo contatti\uff1b<br \/>3. Quando l&#039;operazione \u201copen\u201d, il terminale di dare una \u201caprire completamente il segnale\u201d.;<br \/>4. Quando il \u201dfuori\u201c \u00e8 a posto, il terminal 5 uscite di un \u201doff del segnale&#034;.;<br \/>5. Terminale 7 filo di terra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-e3d71b9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e3d71b9\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-98695b9\" data-id=\"98695b9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-30aff6d elementor-widget elementor-widget-heading\" data-id=\"30aff6d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo H: CA trifase circuito di controllo passivo interruttore di contatto<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4e9fe9 elementor-widget elementor-widget-image\" data-id=\"b4e9fe9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"412\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-h.webp\" class=\"attachment-full size-full wp-image-4854\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668H\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-h.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-h-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb8b4e9 elementor-widget elementor-widget-text-editor\" data-id=\"cb8b4e9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Attraverso un esterno inversione del circuito, il motore viene ruotato in avanti e in retromarcia, in modo da realizzare \u201con\u201d e \u201coff\u201d operazioni e uscita completamente e completamente passivo segnali.<\/p><p><strong>Istruzioni per il cablaggio\uff1a<\/strong><br \/>1. I terminal 1, 2 e 3 sono collegati a tre-fase di alimentazione CA, e il motore \u00e8 rivolto in avanti e indietro, attraverso un esterno inversione del circuito.\uff1b<br \/>2. Il Terminal 4 \u00e8 il comune terminale del circuito di controllo esterno\uff1b<br \/>3. Il Terminal 5 \u00e8 \u201coff\u201d, l&#039;operazione di controllo\uff1b<br \/>4. Terminale 6 \u00e8 \u201csul\u201d controllo del funzionamento\uff1b<br \/>5. Terminale di 7 comune di terminale passivo di contatti\uff1b<br \/>6. Quando l&#039;operazione \u201copen\u201d, il terminale invia un \u201caprire completamente il segnale\u201c.;<br \/>7. Quando il \u201dfuori\u201c \u00e8 a posto, terminale di 9 uscite, una \u201cfull off del segnale&#034;.\uff1b<br \/>8. Morsetto 12 filo di terra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c0158b3\" data-id=\"c0158b3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u9632\u7206\u7cfb\u5217\/\u666e\u901a\u7cfb\u5217\/\u5feb\u5f00\u7cfb\u5217\u7684\u5f00\u5173\u578b\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a \u666e\u901a\u7cfb\u5217\uff1aDCL-05\/DCL-10 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6913,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[387,378,44,34,42,41],"class_list":["post-6032","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-trouble-shooting-guide","tag-on-off-actuator","tag-fast-move-actuator","tag-actuator","tag-general-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/posts\/6032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/comments?post=6032"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/posts\/6032\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/media\/6913"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/media?parent=6032"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/categories?post=6032"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/tags?post=6032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}