{"id":5380,"date":"2023-06-05T16:19:39","date_gmt":"2023-06-05T08:19:39","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5380"},"modified":"2025-04-18T14:18:11","modified_gmt":"2025-04-18T06:18:11","slug":"why-voltage-signal-oscillate","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/it_it\/support\/an-actuator\/why-voltage-signal-oscillate","title":{"rendered":"Perch\u00e9 la tensione-tipo di segnale di uscita oscillare in determinate condizioni di funzionamento?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5380\" class=\"elementor elementor-5380\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1893469 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"1893469\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-61d5be0\" data-id=\"61d5be0\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b816885 elementor-align-left elementor-widget elementor-widget-post-info\" data-id=\"b816885\" data-element_type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-847a4e2 elementor-inline-item\" itemprop=\"author\">\n\t\t\t\t\t\t<a href=\"https:\/\/www.dcl-controls.com\/it_it\/author\/admin\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-far-user-circle\" viewbox=\"0 0 496 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M248 104c-53 0-96 43-96 96s43 96 96 96 96-43 96-96-43-96-96-96zm0 144c-26.5 0-48-21.5-48-48s21.5-48 48-48 48 21.5 48 48-21.5 48-48 48zm0-240C111 8 0 119 0 256s111 248 248 248 248-111 248-248S385 8 248 8zm0 448c-49.7 0-95.1-18.3-130.1-48.4 14.9-23 40.4-38.6 69.6-39.5 20.8 6.4 40.6 9.6 60.5 9.6s39.7-3.1 60.5-9.6c29.2 1 54.7 16.5 69.6 39.5-35 30.1-80.4 48.4-130.1 48.4zm162.7-84.1c-24.4-31.4-62.1-51.9-105.1-51.9-10.2 0-26 9.6-57.6 9.6-31.5 0-47.4-9.6-57.6-9.6-42.9 0-80.6 20.5-105.1 51.9C61.9 339.2 48 299.2 48 256c0-110.3 89.7-200 200-200s200 89.7 200 200c0 43.2-13.9 83.2-37.3 115.9z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-author\">\n\t\t\t\t\t\t\t\t\t\tDCL Controls\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-7014cca elementor-inline-item\" itemprop=\"datePublished\">\n\t\t\t\t\t\t<a href=\"https:\/\/www.dcl-controls.com\/it_it\/2023\/06\/05\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-calendar\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M12 192h424c6.6 0 12 5.4 12 12v260c0 26.5-21.5 48-48 48H48c-26.5 0-48-21.5-48-48V204c0-6.6 5.4-12 12-12zm436-44v-36c0-26.5-21.5-48-48-48h-48V12c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v52H160V12c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v52H48C21.5 64 0 85.5 0 112v36c0 6.6 5.4 12 12 12h424c6.6 0 12-5.4 12-12z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-date\">\n\t\t\t\t\t\t\t\t\t\t<time>Giugno 5, 2023<\/time>\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-05722c0 elementor-widget elementor-widget-image\" data-id=\"05722c0\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"960\" height=\"299\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/voltage-signal-path.webp\" class=\"attachment-full size-full wp-image-5384\" alt=\"0~5V\uff0c0~10V\u7535\u538b\u4fe1\u53f7\u4f20\u8f93\u9014\u5f84 | Voltage signal coupling path\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/voltage-signal-path.webp 960w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/voltage-signal-path-18x6.webp 18w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 1 Il percorso di trasmissione della sorgente di tensione del segnale<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f64e7bf elementor-widget elementor-widget-text-editor\" data-id=\"f64e7bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Come mostrato in Figura 1, la trasmissione della sorgente di tensione del segnale \u00e8 principalmente composto di 3 parti\uff1a<\/strong><\/p><ol><li>Feedback negativo tipo di segnale di tensione di uscita del circuito.<\/li><li>La trasmissione del segnale via cavo. Tra di loro, C1 L1 capacit\u00e0 parassita e parassitarie induttanza del cavo, e i relativi parametri sono direttamente correlati alla lunghezza del cavo e cablaggio tipo.<\/li><li>Segnale di ingresso acquisizione circuito. Tra di loro, L2 e C2 sono il filtro low-pass circuiti che possono essere organizzati in una parte del circuito di campionamento.<\/li><\/ol><p>Per il feedback negativo del segnale di tensione di uscita del circuito, la formula per il calcolo del segnale di ingresso \u00e8 come segue: per<\/p><p>\u00a0 \u00a0 \u00a0 \u00a0 \u2223Xi&#039;\u2223=\u2223Xi\u2223\u2212\u2223Xf\u2223<\/p><p>Quando la fase ofXXf\u2223 scadenza o ritardi di 180\u00b0, la formula per il calcolo del segnale di ingresso diventa il seguente modulo di iscrizione:<\/p><p>\u00a0 \u00a0 \u00a0 \u00a0 \u2223Xi&#039;\u2223=\u2223Xi\u2223+\u2223Xf\u2223<\/p><p>In altre parole, in assenza di un segnale di ingresso (XiXiXi \u00e8 0), il segnale di feedback (XXf\u2223) mantiene il segnale di uscita (|X0|), e il segnale di uscita (|X0|), in grado di mantenere il segnale di feedback (XXf\u2223). In questo momento, l&#039;auto-eccitato oscillazione \u00e8 formata.<\/p><p>Tutto sommato, le due condizioni seguenti sono i prerequisiti per l&#039;auto-eccitato oscillazione\uff1a<\/p><ol><li>|AF| &gt; 1<\/li><li>\u03c6A+\u03c6F=(2n+1)\u03a0<\/li><\/ol><p><strong>Da dove viene la differenza di fase nel ciclo di venire da?<\/strong><\/p><p>Parassitarie C1 e L1 sulla trasmissione del segnale via cavo, L2 e C2 del segnale di ingresso acquisizione circuito, e condensatori di filtro sul segnale, circuito di uscita pu\u00f2 essere causa di differenze di fase in anticipo o isteresi. La fase finale differenza \u00e8 la somma di queste differenze di fase. Se il periodo \u00e8 in ritardo o l&#039;isteresi \u00e8 di 180\u00b0, \u00e8 possibile auto-eccitare l&#039;oscillazione.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0085879 elementor-widget elementor-widget-text-editor\" data-id=\"0085879\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Come evitare di auto-eccitato oscillazione?<\/strong><\/p><p>Abbiamo solo bisogno di assicurarsi che all&#039;interno della gamma del dominio di frequenza, le suddette due condizioni non possono essere soddisfatte contemporaneamente, in modo che l&#039;auto-eccitato di oscillazione pu\u00f2 essere evitato.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26b0ed9 elementor-widget elementor-widget-image\" data-id=\"26b0ed9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"417\" height=\"415\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/self-excited-oscilation-factor.webp\" class=\"attachment-full size-full wp-image-5382\" alt=\"\u8d1f\u53cd\u9988\u7535\u8def\u4e0d\u53d1\u751f\u632f\u8361\u7684\u6761\u4ef6\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/self-excited-oscilation-factor.webp 417w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/self-excited-oscilation-factor-12x12.webp 12w\" sizes=\"(max-width: 417px) 100vw, 417px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 2 La condizione che il ciclo di feedback negativo non oscilla<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5973d4f elementor-widget elementor-widget-text-editor\" data-id=\"5973d4f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Come mostrato in Figura 2\uff1a<\/p><p>f \u00e8 la frequenza in cui il guadagno del loop di 20log|AF|gocce di 0dB.<\/p><p>f \u00e8 la frequenza in cui la differenza di fase del ciclo \u00e8 inferiore a -180\u00b0.<\/p><p>Di conseguenza, quando la differenza di fase \u00e8 scaduta o se l&#039;isteresi \u00e8 di 180\u00b0, il guadagno del loop scende sotto lo 0, e il circuito \u00e8 stabile.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9348ff8 elementor-widget elementor-widget-text-editor\" data-id=\"9348ff8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Relativamente parlando, perch\u00e9 \u00e8 la sorgente di corrente del segnale non \u00e8 facile oscillare?<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4f108dc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4f108dc\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c18ac4e\" data-id=\"c18ac4e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7819e21 elementor-widget elementor-widget-image\" data-id=\"7819e21\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"406\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/current-signal-feedback-path.webp\" class=\"attachment-full size-full wp-image-5381\" alt=\"\u7535\u6d41\u4fe1\u53f7\u8f93\u51fa\u7535\u8def\u7684\u53cd\u9988\u56de\u8def | Current Signal feedback path\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/current-signal-feedback-path.webp 600w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/current-signal-feedback-path-18x12.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 3 fonte di Corrente ciclo di feedback<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-a46cc41\" data-id=\"a46cc41\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2a32944 elementor-widget elementor-widget-image\" data-id=\"2a32944\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"586\" height=\"425\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/voltage-signal-feedback-path.webp\" class=\"attachment-full size-full wp-image-5386\" alt=\"\u7535\u538b\u4fe1\u53f7\u8f93\u51fa\u7535\u8def\u7684\u53cd\u9988\u56de\u8def | Voltage signal feekback path\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/voltage-signal-feedback-path.webp 586w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/why-voltage-signal-self-excited-oscillate\/images\/voltage-signal-feedback-path-18x12.webp 18w\" sizes=\"(max-width: 586px) 100vw, 586px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 4 fonte di Tensione di feedback loop<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-f733503 elementor-widget elementor-widget-text-editor\" data-id=\"f733503\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Come mostrato in Figura 2, l&#039;uscita della sorgente di corrente che \u00e8 attualmente ampiamente utilizzato \u00e8 lo specchio di corrente. La sua negative feedback loop di regolazione contiene solo un lato dello specchio sorgente di corrente identificato dalla linea rossa. Pertanto, il circuito di carico esterno ha poco effetto sulla differenza di fase e di guadagno dell&#039;anello di retroazione. Fintanto che i parametri dell&#039;interno ciclo di feedback sono controllati, nessuna oscillazione si verificher\u00e0.<\/p><p>Come mostrato in Figura 3, il feedback punto di tensione del segnale sorgente \u00e8 situata presso il punto di uscita del circuito. Pertanto, il ciclo di feedback contiene il circuito interno indicato dalla linea rossa e il cavo esterno e di campionamento del circuito. In questo modo, quando i parametri elettrici del cavo esterno o di campionamento modifica di cavo, la differenza di fase e di guadagno del ciclo di feedback negativo anche cambiare. Quando questo cambiamento soddisfa le due condizioni di auto-eccitato oscillazione, oscillazione si verifica.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-36f721e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"36f721e\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-855bb4c\" data-id=\"855bb4c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0bcd777 elementor-align-left elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"0bcd777\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/it_it\/tech-enquiry\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Consulenza tecnica<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-20d88f5\" data-id=\"20d88f5\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-df7c27e elementor-align-left elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"df7c27e\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/it_it\/where-to-buy\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ordine prodotto<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-e508c63\" data-id=\"e508c63\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-inner-column elementor-element elementor-element-71f0089\" data-id=\"71f0089\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a86a8f elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"5a86a8f\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57a91d2 elementor-widget elementor-widget-text-editor\" data-id=\"57a91d2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Articoli tecnici inerenti\uff1a<\/p><ul><li><a href=\"\/it_it\/tech\/actuator-immunity-4-20ma-vs-2-10v\/\">Grande concorso per la prestazione anti-interferenza di attuatori elettrici (4-20mA VS 2-10V)<\/a><\/li><\/ul><p>Relative norme tecniche<\/p><ul><li><a href=\"\/it_it\/tech\/gb-t-3369-1-2008-iec-60381-1-1982\/\">GB\/T 3369.1\u20142008\/IEC 60381-1:1982 segnali Analogici per i sistemi di controllo di processo-Parte 1: segnali di corrente DC<\/a><\/li><li><a href=\"\/it_it\/tech\/gb-t-3369-2-2008-iec-60381-2-1978\/\">GB\/T 3369.2\u20142008\/IEC 60381-2:1978 segnali Analogici per i sistemi di controllo di processo-Parte 2: DC segnali di tensione<\/a><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c41a453 elementor-widget elementor-widget-text-editor\" data-id=\"c41a453\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"text-decoration: underline;\"><a href=\"#top\">Torna all&#039;inizio<\/a><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u56fe1 \u7535\u538b\u6e90\u4fe1\u53f7\u7684\u4f20\u8f93\u9014\u5f84 \u5982\u56fe1\uff0c\u7535\u538b\u6e90\u4fe1\u53f7\u7684\u4f20\u8f93\u4e3b\u8981\u75313\u90e8\u5206\u7ec4\u6210\uff1a \u8d1f\u53cd\u9988\u578b\u7535\u538b\u4fe1\u53f7\u8f93\u51fa\u7535\u8def\u3002 \u4fe1\u53f7\u4f20\u8f93\u7535 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6531,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[646],"tags":[386,44,34,42,373,41],"class_list":["post-5380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-an-actuator","tag-faq","tag-fast-move-actuator","tag-actuator","tag-general-actuator","tag-very-small-actuator-tag","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/posts\/5380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/comments?post=5380"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/posts\/5380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/media\/6531"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/media?parent=5380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/categories?post=5380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/it_it\/wp-json\/wp\/v2\/tags?post=5380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}