{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-04-18T11:35:31","modified_gmt":"2025-04-18T03:35:31","slug":"dcl-02-switch","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/es_pr\/support\/mr-actuator\/dcl-02-switch","title":{"rendered":"Los fallos m\u00e1s comunes y soluci\u00f3n de problemas de DCL-02 accionador del interruptor"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d1ba3c2 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"d1ba3c2\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-13d9a9c\" data-id=\"13d9a9c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d791082 elementor-widget elementor-widget-text-editor\" data-id=\"d791082\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este asistente es adecuado para DCL ultra-peque\u00f1o de la serie de actuadores, los modelos son como sigue\uff1a<\/p><ul><li>DCL-02A \/ DCL-02B \/ DCL-02G<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb92161 elementor-widget elementor-widget-image\" data-id=\"cb92161\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | DCL-02 Actuator Valve\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve.webp 176w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve-132x300.webp 132w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve-5x12.webp 5w\" sizes=\"(max-width: 176px) 100vw, 176px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8500e7 elementor-widget elementor-widget-heading\" data-id=\"e8500e7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Los fallos m\u00e1s comunes y los m\u00e9todos de soluci\u00f3n de problemas.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4741093 elementor-widget elementor-widget-shortcode\" data-id=\"4741093\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-35\" class=\"tablepress tablepress-id-35 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">la culpa<\/th><th class=\"column-2\">Posible causa<\/th><th class=\"column-3\">M\u00e9todo de exclusi\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\">El actuador no se enciende o apaga cuando se inicia por primera vez<\/td><td class=\"column-2\">1. Un cableado incorrecto<\/td><td class=\"column-3\">Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. Una alimentaci\u00f3n incorrecta<\/td><td class=\"column-3\">Confirme que el voltaje de salida de la fuente de alimentaci\u00f3n es de \u00b110% de la tensi\u00f3n nominal del actuador, y la corriente de salida es de 3 veces la corriente nominal del actuador.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. \u63a7\u5236\u5f00\u5173\u6216\u63a7\u5236\u7ee7\u7535\u5668\u5f02\u5e38<\/td><td class=\"column-3\">\u4f7f\u7528\u4e07\u7528\u8868\u6d4b\u91cf\u6267\u884c\u5668\u5f00\u5173\u63a7\u5236\u7aef\u7684\u8f93\u5165\u7535\u538b\uff0c\u786e\u8ba4\u662f\u5426\u7b26\u5408\u9884\u671f\uff1f<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. \u63a7\u5236\u7cfb\u7edf\u5339\u914d\u95ee\u9898<\/td><td class=\"column-3\">1. El uso de un interruptor mec\u00e1nico para medir la funci\u00f3n del actuador. Si el actuador se encuentra funcionando normalmente, compruebe si la salida de la l\u00f3gica del sistema de control cumple con las expectativas?<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. \u591a\u4e2a\u6267\u884c\u5668\u6216\u6267\u884c\u5668\u548c\u5176\u5b83\u8bbe\u5907\u5e76\u8054<\/td><td class=\"column-3\">\u5f00\u5173\u578b\u6267\u884c\u5668\u662f\u901a\u8fc7\u542f\u52a8\u7535\u5bb9\u5b8c\u6210\u542f\u52a8\u7684\uff0c\u548c\u5176\u5b83\u8bbe\u5907\u5e76\u8054\u5c06\u5bf9\u542f\u52a8\u7535\u5bb9\u7684\u5bb9\u503c\u4ea7\u751f\u5f71\u54cd\u3002\u6240\u4ee5\uff0c\u5f00\u5173\u578b\u6267\u884c\u5668\u53ea\u80fd\u4f7f\u7528\u5355\u8def\u63a7\u5236\uff0c\u4e0d\u80fd\u5e76\u8054\u3002<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td rowspan=\"2\" class=\"column-1\">\u6267\u884c\u5668\u53ea\u80fd\u5f00\u542f\u6216\u5173\u95ed<\/td><td class=\"column-2\">1. Un cableado incorrecto<\/td><td class=\"column-3\">1. El uso de un interruptor mec\u00e1nico para medir la funci\u00f3n del actuador. Si el actuador se encuentra funcionando normalmente, compruebe si la salida de la l\u00f3gica del sistema de control cumple con las expectativas?<br \/>\n2. Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-2\">2. Configuraci\u00f3n incorrecta de totalmente en\/fullyoff cam<\/td><td class=\"column-3\">referencia<a href=\"\/es_pr\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Establezca la posici\u00f3n de la leva correctamente.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td rowspan=\"3\" class=\"column-1\">El actuador se detiene en la mitad del viaje<\/td><td class=\"column-2\">1. V\u00e1lvula de estancamiento<\/td><td class=\"column-3\">Compruebe si la v\u00e1lvula se atasca, eliminar la atascado y vuelva a intentarlo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">2. Potencial de s\u00f3lidos en el l\u00edquido a medio hacer que la v\u00e1lvula se estancan.<\/td><td class=\"column-3\">Compruebe si hay s\u00f3lidos atrapados en el medio fluido, eliminar la v\u00e1lvula atascada, e int\u00e9ntelo de nuevo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">3. Configuraci\u00f3n incorrecta de totalmente encendido\/totalmente apagado tap\u00f3n<\/td><td class=\"column-3\">referencia<a href=\"\/es_pr\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Ajuste el tap\u00f3n de la posici\u00f3n correctamente.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Usando el mango, el actuador no puede ser rotado<\/td><td class=\"column-2\">1. Potencial de s\u00f3lidos en el medio fluido causa la v\u00e1lvula de quedar atrapado.<\/td><td class=\"column-3\">Compruebe si hay s\u00f3lidos atrapados en el medio fluido, eliminar la v\u00e1lvula atascada, e int\u00e9ntelo de nuevo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. V\u00e1lvula atascada<\/td><td class=\"column-3\">Compruebe si la v\u00e1lvula se atasca, eliminar la atascado y vuelva a intentarlo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. El actuador de la desaceleraci\u00f3n mecanismo est\u00e1 da\u00f1ado.<\/td><td class=\"column-3\">Retire el actuador de la v\u00e1lvula y gire la manija. Si no se puede girar, reempl\u00e1celo con un nuevo actuador.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Retroalimentaci\u00f3n de la posici\u00f3n de la se\u00f1al sin salida<\/td><td class=\"column-2\">1. Incorrecta del interruptor cableado<\/td><td class=\"column-3\">Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. Configuraci\u00f3n incorrecta de totalmente en\/fullyoff cam<\/td><td class=\"column-3\">referencia<a href=\"\/es_pr\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Establezca la posici\u00f3n de la leva correctamente.<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. Sobrecorriente causa da\u00f1o a la retroalimentaci\u00f3n de la posici\u00f3n del interruptor de la se\u00f1al.<\/td><td class=\"column-3\">1. referencia<a href=\"\/es_pr\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Compruebe si el totalmente encendido\/fullyoff cam pactos de la retroalimentaci\u00f3n de la posici\u00f3n del interruptor?<br \/>\n2. \u6d4b\u91cf\u4f4d\u7f6e\u53cd\u9988\u56de\u8def\u662f\u5426\u63a5\u901a\uff1f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-35 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c1a5e9 elementor-widget elementor-widget-heading\" data-id=\"0c1a5e9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2\u3001\u8bf7\u6838\u5bf9\u5e94\u7528\u5de5\u51b5\u662f\u5426\u7b26\u5408\u53c2\u6570\u8981\u6c42\u3002<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6033e3a elementor-widget elementor-widget-text-editor\" data-id=\"6033e3a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 \u7535\u52a8\u6267\u884c\u5668\u53ef\u80fd\u4f1a\u56e0\u4f7f\u7528\u4e0d\u5f53\u6216\u5728\u9519\u8bef\u7684\u5e94\u7528\u5de5\u51b5\u4e0b\u800c\u51fa\u73b0\u6545\u969c\u3002\u5728\u7b26\u5408\u4ea7\u54c1\u89c4\u683c\u4e66\u5b9a\u4e49\u7684\u5e94\u7528\u5de5\u51b5\u4e0b\uff0c\u5c06\u53ef\u4ee5\u786e\u4fdd\u6267\u884c\u5668\u957f\u671f\u65e0\u6545\u969c\u8fd0\u884c\u3002<\/p><ul><li><strong>\u4f9b\u7535\u7535\u538b\uff1a<\/strong>El voltaje de la fuente de alimentaci\u00f3n debe estar dentro de la nominal rango de voltaje de operaci\u00f3n del actuador. Sobretensi\u00f3n o subtensi\u00f3n puede causar la vida del actuador a reducirse.<\/li><li><span style=\"font-weight: bold;\">La oferta actual\uff1a<\/span>Desde la corriente de arranque del motor es mucho mayor que la corriente nominal. Para garantizar el funcionamiento fiable del actuador, por favor, utilice una fuente de alimentaci\u00f3n con una capacidad de salida de corriente mayor que 3 veces la corriente nominal del actuador.<\/li><li><strong>la temperatura\uff1a<\/strong>\u786e\u4fdd\u6267\u884c\u5668\u5728\u989d\u5b9a\u7684\u5de5\u4f5c\u6e29\u5ea6\u8303\u56f4\u5185\u8fd0\u884c\u3002\u5728\u8d85\u51fa\u989d\u5b9a\u5de5\u4f5c\u6e29\u5ea6\u8303\u56f4\u7684\u73af\u5883\u4e0b\u4f7f\u7528\u6267\u884c\u5668\uff0c\u53ef\u80fd\u5bfc\u81f4\u6267\u884c\u5668\u529f\u80fd\u4e0d\u826f\u6216\u4f7f\u7528\u5bff\u547d\u964d\u4f4e\uff0c\u5e76\u6700\u7ec8\u5bfc\u81f4\u6267\u884c\u5668\u5931\u6548\u3002<\/li><li><strong>\u73af\u5883\uff1a<\/strong>DCL\u5f00\u5173\u578b\u6267\u884c\u673a\u6784\u5177\u6709IP67\u9632\u98ce\u96e8\u7b49\u7ea7\u3002\u4e00\u822c\u9002\u7528\u4e8e\u5ba4\u5185\u6216\u5ba4\u5916\u5e94\u7528\u3002\u63d0\u4f9b\u4e00\u5b9a\u7a0b\u5ea6\u7684\u9632\u96e8\u3001\u9632\u6e85\u6c34\u3002\u4fdd\u62a4\u6267\u884c\u5668\u514d\u53d7\u96e8\u6dcb\uff0c\u96ea\u3001\u51b0\u548c\u7d2b\u5916\u7ebf\uff08\u9633\u5149\uff09\u901a\u5e38\u4f1a\u5ef6\u957f\u4ea7\u54c1\u7684\u5bff\u547d\u3002\u975e\u5e38\u8150\u8680\u6027\u73af\u5883\u53ef\u80fd\u5bfc\u81f4\u7535\u5b50\u8bbe\u5907\u8fc7\u65e9\u5931\u6548\u3002\u4e0d\u8981\u5728\u9632\u7206\u73af\u5883\u4e0b\u4f7f\u7528\u975e\u9632\u7206\u7cfb\u5217\u7684\u6267\u884c\u5668\u3002<\/li><li><strong>\u901a\u7535\u6301\u7eed\u7387\uff1a<\/strong>DCL\u5f00\u5173\u578b\u6267\u884c\u5668\u7684\u901a\u7535\u6301\u7eed\u7387\u4e3a70%\uff08\u6bcf\u5206\u949f\u8fd0\u884c42\u79d2\uff0c\u5fc5\u987b\u5173\u95ed18\u79d2\uff09\uff0c\u8d85\u8fc770%\u7684\u901a\u7535\u6301\u7eed\u7387\u5c06\u5bfc\u81f4\u7535\u673a\u8fdb\u5165\u8fc7\u70ed\u4fdd\u62a4\u3002<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e6a596 elementor-widget elementor-widget-heading\" data-id=\"5e6a596\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3\u3001\u68c0\u67e5\u6267\u884c\u5668\u7684\u63a5\u7ebf\u662f\u5426\u6b63\u786e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-21e06a8 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"21e06a8\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-b9bec88\" data-id=\"b9bec88\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-dcbb3bd elementor-widget elementor-widget-heading\" data-id=\"dcbb3bd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo a: Con l\u00edmite de posici\u00f3n de interruptor (contacto activo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e3675c elementor-widget elementor-widget-image\" data-id=\"8e3675c\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a-14x12.webp 14w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c8f5f elementor-widget elementor-widget-text-editor\" data-id=\"a8c8f5f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El &#034;on&#034; y &#034;off&#034; de las operaciones se realiza a trav\u00e9s de la conmutaci\u00f3n de circuitos, y un conjunto de completamente y totalmente off activa las se\u00f1ales de salida.<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La Terminal 1 est\u00e1 conectado a la l\u00ednea media de la fuente de alimentaci\u00f3n\uff1b<br \/>2. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 2 est\u00e1 activada, es &#034;off&#034; de la operaci\u00f3n.\uff1b<br \/>3. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 3 est\u00e1 activada, es &#034;en la operaci\u00f3n&#034;.\uff1b<br \/>4. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 2 est\u00e1 conectado y el &#034;off&#034; de la operaci\u00f3n est\u00e1 en su lugar, el &#034;apagado total de la se\u00f1al de&#034; indicador de luz conectado a la terminal 4 es en.\uff1b<br \/>5. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 3 est\u00e1 conectado y el &#034;sobre&#034; la operaci\u00f3n est\u00e1 en su lugar, el &#034;totalmente abierta, la se\u00f1al de&#034; indicador de luz conectado a la terminal 5 es en.\uff1b<br \/>6. En la Terminal 7 del alambre de tierra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c18850d\" data-id=\"c18850d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-268e895 elementor-widget elementor-widget-heading\" data-id=\"268e895\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo B: Con un nivel intermedio de posici\u00f3n de interruptor (contacto pasivo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69294ea elementor-widget elementor-widget-image\" data-id=\"69294ea\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad85b91 elementor-widget elementor-widget-text-editor\" data-id=\"ad85b91\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El &#034;on&#034; y &#034;off&#034; de las operaciones se realiza a trav\u00e9s de la conmutaci\u00f3n de circuitos, y un conjunto de totalmente y completamente fuera de pasivo de las se\u00f1ales de salida.<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La Terminal 1 est\u00e1 conectado a la l\u00ednea media de la fuente de alimentaci\u00f3n\uff1b<br \/>2. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 2 est\u00e1 activada, es &#034;off&#034; de la operaci\u00f3n.\uff1b<br \/>3. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 3 est\u00e1 activada, es &#034;en la operaci\u00f3n&#034;.\uff1b<br \/>4. La Terminal 4 es el terminal com\u00fan de pasivo contactos\uff1b<br \/>5. Cuando la operaci\u00f3n de &#034;open&#034; est\u00e1 en su lugar, la terminal 5 salidas de un &#034;totalmente se\u00f1al abierta&#034;.;<br \/>6. Cuando el &#034;off&#034; en el lugar, el terminal se compila un &#034;apagado total de la se\u00f1al&#034;. \uff1b<br \/>7. En la Terminal 7 del alambre de tierra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-ebb5092 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"ebb5092\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9080197\" data-id=\"9080197\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d3aa831 elementor-widget elementor-widget-heading\" data-id=\"d3aa831\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo G: DC circuito de control pasivo con interruptor de contacto<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3259f4b elementor-widget elementor-widget-image\" data-id=\"3259f4b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7109c8 elementor-widget elementor-widget-text-editor\" data-id=\"a7109c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De acuerdo a la unidireccional de la conductividad del diodo, por los desplazamientos de los aspectos positivos y negativos de los electrodos de la fuente de alimentaci\u00f3n de CC, el &#034;on&#034; y &#034;off&#034; de las operaciones se realizan y un conjunto de totalmente y completamente fuera de pasivo de las se\u00f1ales de salida.<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La Terminal 1 est\u00e1 conectado al electrodo positivo de la fuente de alimentaci\u00f3n y el terminal 2 es &#034;off&#034; operaci\u00f3n cuando est\u00e1 conectado al electrodo negativo de la fuente de alimentaci\u00f3n; la terminal 2 est\u00e1 conectado al electrodo positivo de la fuente de alimentaci\u00f3n y el terminal 1 es &#034;en la&#034; operaci\u00f3n cuando est\u00e1 conectado al electrodo negativo de la fuente de alimentaci\u00f3n.\uff1b<br \/>2. La Terminal 3 es el terminal com\u00fan de pasivo contactos\uff1b<br \/>3. Cuando la operaci\u00f3n de &#034;open&#034; est\u00e1 en su lugar, el terminal tiene una &#034;totalmente se\u00f1al abierta&#034;.;<br \/>4. Cuando el &#034;off&#034; en el lugar, la terminal 5 salidas de un &#034;apagado total de la se\u00f1al&#034;.;<br \/>5. En la Terminal 7 del alambre de tierra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0934aa3\" data-id=\"0934aa3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c9aedd elementor-widget elementor-widget-text-editor\" data-id=\"7c9aedd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Al llevar a cabo una investigaci\u00f3n en el sitio del proyecto, puede contactar con nuestra empresa de servicio t\u00e9cnico de personal tan pronto como sea posible para investigar las fallas y determinar la soluci\u00f3n.<\/em><br \/><em>N\u00famero de contacto: 13026331611 (Chen Gong)<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u8d85\u5c0f\u7cfb\u5217\u7684\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a DCL-02A \/ DCL-02B \/ DCL-02G 1\u3001\u5e38 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5251,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[374,375,387,34,373],"class_list":["post-6033","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-dcl-02","tag-dcl-02-on-off","tag-trouble-shooting-guide","tag-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/media\/5251"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_pr\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}