{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-04-18T11:35:31","modified_gmt":"2025-04-18T03:35:31","slug":"dcl-02-switch","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/es_mx\/support\/mr-actuator\/dcl-02-switch","title":{"rendered":"Los fallos m\u00e1s comunes y soluci\u00f3n de problemas de DCL-02 accionador del interruptor"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d1ba3c2 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"d1ba3c2\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-13d9a9c\" data-id=\"13d9a9c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d791082 elementor-widget elementor-widget-text-editor\" data-id=\"d791082\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este asistente es adecuado para DCL ultra-peque\u00f1o de la serie de actuadores, los modelos son como sigue\uff1a<\/p><ul><li>DCL-02A \/ DCL-02B \/ DCL-02G<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb92161 elementor-widget elementor-widget-image\" data-id=\"cb92161\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | DCL-02 Actuator Valve\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve.webp 176w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve-132x300.webp 132w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/shelf-banner\/dcl-02-valve-5x12.webp 5w\" sizes=\"(max-width: 176px) 100vw, 176px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8500e7 elementor-widget elementor-widget-heading\" data-id=\"e8500e7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Los fallos m\u00e1s comunes y los m\u00e9todos de soluci\u00f3n de problemas.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4741093 elementor-widget elementor-widget-shortcode\" data-id=\"4741093\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-35\" class=\"tablepress tablepress-id-35 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">la culpa<\/th><th class=\"column-2\">Posible causa<\/th><th class=\"column-3\">M\u00e9todo de exclusi\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\">El actuador no se enciende o apaga cuando se inicia por primera vez<\/td><td class=\"column-2\">1. Un cableado incorrecto<\/td><td class=\"column-3\">Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. Una alimentaci\u00f3n incorrecta<\/td><td class=\"column-3\">Confirme que el voltaje de salida de la fuente de alimentaci\u00f3n es de \u00b110% de la tensi\u00f3n nominal del actuador, y la corriente de salida es de 3 veces la corriente nominal del actuador.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. Anormal de control de interruptor o rel\u00e9 de control<\/td><td class=\"column-3\">Utilice un mult\u00edmetro para medir el voltaje de entrada en el terminal de control del accionador de interruptor para confirmar si cumple con las expectativas?<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. Sistema de Control de coincidencia de problema<\/td><td class=\"column-3\">El uso de un interruptor mec\u00e1nico para medir la funci\u00f3n del actuador. Si el actuador se encuentra funcionando normalmente, compruebe si la salida de la l\u00f3gica del sistema de control cumple con las expectativas?<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. Varios actuadores o actuadores en paralelo con otros equipos<\/td><td class=\"column-3\">El actuador de conmutaci\u00f3n se inicia a trav\u00e9s del condensador de arranque, y en paralelo con otros equipos tienen un impacto en el valor de capacitancia del condensador de arranque. Por lo tanto, el actuador de conmutaci\u00f3n s\u00f3lo se puede usar un solo control, no en paralelo.<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td rowspan=\"2\" class=\"column-1\">El actuador s\u00f3lo puede ser activado o desactivado<\/td><td class=\"column-2\">1. Un cableado incorrecto<\/td><td class=\"column-3\">1. El uso de un interruptor mec\u00e1nico para medir la funci\u00f3n del actuador. Si el actuador se encuentra funcionando normalmente, compruebe si la salida de la l\u00f3gica del sistema de control cumple con las expectativas?<br \/>\n2. Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-2\">2. Configuraci\u00f3n incorrecta de totalmente en\/fullyoff cam<\/td><td class=\"column-3\">referencia<a href=\"\/es_mx\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Establezca la posici\u00f3n de la leva correctamente.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td rowspan=\"3\" class=\"column-1\">El actuador se detiene en la mitad del viaje<\/td><td class=\"column-2\">1. V\u00e1lvula de estancamiento<\/td><td class=\"column-3\">Compruebe si la v\u00e1lvula se atasca, eliminar la atascado y vuelva a intentarlo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">2. Potencial de s\u00f3lidos en el l\u00edquido a medio hacer que la v\u00e1lvula se estancan.<\/td><td class=\"column-3\">Compruebe si hay s\u00f3lidos atrapados en el medio fluido, eliminar la v\u00e1lvula atascada, e int\u00e9ntelo de nuevo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">3. Configuraci\u00f3n incorrecta de totalmente encendido\/totalmente apagado tap\u00f3n<\/td><td class=\"column-3\">referencia<a href=\"\/es_mx\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Ajuste el tap\u00f3n de la posici\u00f3n correctamente.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Usando el mango, el actuador no puede ser rotado<\/td><td class=\"column-2\">1. Potencial de s\u00f3lidos en el medio fluido causa la v\u00e1lvula de quedar atrapado.<\/td><td class=\"column-3\">Compruebe si hay s\u00f3lidos atrapados en el medio fluido, eliminar la v\u00e1lvula atascada, e int\u00e9ntelo de nuevo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. V\u00e1lvula atascada<\/td><td class=\"column-3\">Compruebe si la v\u00e1lvula se atasca, eliminar la atascado y vuelva a intentarlo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. El actuador de la desaceleraci\u00f3n mecanismo est\u00e1 da\u00f1ado.<\/td><td class=\"column-3\">Retire el actuador de la v\u00e1lvula y gire la manija. Si no se puede girar, reempl\u00e1celo con un nuevo actuador.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Retroalimentaci\u00f3n de la posici\u00f3n de la se\u00f1al sin salida<\/td><td class=\"column-2\">1. Incorrecta del interruptor cableado<\/td><td class=\"column-3\">Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. Configuraci\u00f3n incorrecta de totalmente en\/fullyoff cam<\/td><td class=\"column-3\">referencia<a href=\"\/es_mx\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Establezca la posici\u00f3n de la leva correctamente.<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. Sobrecorriente causa da\u00f1o a la retroalimentaci\u00f3n de la posici\u00f3n del interruptor de la se\u00f1al.<\/td><td class=\"column-3\">1. referencia<a href=\"\/es_mx\/faq\/actuator\/set-up-dcl-valve\/\">&#034;C\u00f3mo configurar un interruptor de tipo de v\u00e1lvula El\u00e9ctrica&#034;<\/a>, Compruebe si el totalmente encendido\/fullyoff cam pactos de la retroalimentaci\u00f3n de la posici\u00f3n del interruptor?<br \/>\n2. Es el bucle de retroalimentaci\u00f3n de la posici\u00f3n de medici\u00f3n activado?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-35 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c1a5e9 elementor-widget elementor-widget-heading\" data-id=\"0c1a5e9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Por favor, compruebe si la aplicaci\u00f3n de las condiciones de satisfacer los requisitos de par\u00e1metro.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6033e3a elementor-widget elementor-widget-text-editor\" data-id=\"6033e3a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 El actuador el\u00e9ctrico puede fallar debido a un uso indebido o en virtud de la aplicaci\u00f3n incorrecta de las condiciones. En virtud de la aplicaci\u00f3n de las condiciones definidas en la especificaci\u00f3n de producto, en el largo plazo de la operaci\u00f3n libre de problemas del actuador estar\u00e1 garantizada.<\/p><ul><li><strong>Tensi\u00f3n de alimentaci\u00f3n\uff1a<\/strong>El voltaje de la fuente de alimentaci\u00f3n debe estar dentro de la nominal rango de voltaje de operaci\u00f3n del actuador. Sobretensi\u00f3n o subtensi\u00f3n puede causar la vida del actuador a reducirse.<\/li><li><span style=\"font-weight: bold;\">La oferta actual\uff1a<\/span>Desde la corriente de arranque del motor es mucho mayor que la corriente nominal. Para garantizar el funcionamiento fiable del actuador, por favor, utilice una fuente de alimentaci\u00f3n con una capacidad de salida de corriente mayor que 3 veces la corriente nominal del actuador.<\/li><li><strong>la temperatura\uff1a<\/strong>Aseg\u00farese de que el actuador opera dentro de la nominal rango de temperatura de funcionamiento. El uso del actuador en un entorno que supera la tensi\u00f3n nominal rango de temperatura de operaci\u00f3n puede conducir a una mala funci\u00f3n de actuador o disminuci\u00f3n de la vida \u00fatil, y en \u00faltima instancia conducir a la falla del actuador.<\/li><li><strong>medio ambiente\uff1a<\/strong>El DCL interruptor de tipo de actuador tiene un grado de protecci\u00f3n IP67 resistente a la intemperie clasificaci\u00f3n. Por lo general, adecuado para aplicaciones en interiores y exteriores. Proporcionar un cierto grado de lluvia y las salpicaduras de protecci\u00f3n. Proteger el actuador de la lluvia, la nieve, el hielo y la luz ultravioleta (luz solar) generalmente se prolonga la vida \u00fatil del producto. Muy ambientes corrosivos puede causar el fallo prematuro de los equipos electr\u00f3nicos. No use no es a prueba de explosi\u00f3n serie de actuadores en una prueba de explosiones de medio ambiente.<\/li><li><strong>El poder-sobre la continuidad de la tasa\uff1a<\/strong>El poder-sobre la continuidad de la tasa de la DCL actuador de conmutaci\u00f3n es de 70% (pasa de 42 segundos por minuto y deben estar apagados durante 18 segundos). M\u00e1s del 70% de la energ\u00eda en la continuidad de la tarifa de la causa el motor para entrar de protecci\u00f3n de sobrecalentamiento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e6a596 elementor-widget elementor-widget-heading\" data-id=\"5e6a596\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Compruebe si el cableado del actuador es correcta<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-21e06a8 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"21e06a8\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-b9bec88\" data-id=\"b9bec88\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-dcbb3bd elementor-widget elementor-widget-heading\" data-id=\"dcbb3bd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo a: Con l\u00edmite de posici\u00f3n de interruptor (contacto activo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e3675c elementor-widget elementor-widget-image\" data-id=\"8e3675c\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-a-14x12.webp 14w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c8f5f elementor-widget elementor-widget-text-editor\" data-id=\"a8c8f5f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El &#034;on&#034; y &#034;off&#034; de las operaciones se realiza a trav\u00e9s de la conmutaci\u00f3n de circuitos, y un conjunto de completamente y totalmente off activa las se\u00f1ales de salida.<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La Terminal 1 est\u00e1 conectado a la l\u00ednea media de la fuente de alimentaci\u00f3n\uff1b<br \/>2. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 2 est\u00e1 activada, es &#034;off&#034; de la operaci\u00f3n.\uff1b<br \/>3. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 3 est\u00e1 activada, es &#034;en la operaci\u00f3n&#034;.\uff1b<br \/>4. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 2 est\u00e1 conectado y el &#034;off&#034; de la operaci\u00f3n est\u00e1 en su lugar, el &#034;apagado total de la se\u00f1al de&#034; indicador de luz conectado a la terminal 4 es en.\uff1b<br \/>5. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 3 est\u00e1 conectado y el &#034;sobre&#034; la operaci\u00f3n est\u00e1 en su lugar, el &#034;totalmente abierta, la se\u00f1al de&#034; indicador de luz conectado a la terminal 5 es en.\uff1b<br \/>6. En la Terminal 7 del alambre de tierra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c18850d\" data-id=\"c18850d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-268e895 elementor-widget elementor-widget-heading\" data-id=\"268e895\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo B: Con un nivel intermedio de posici\u00f3n de interruptor (contacto pasivo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69294ea elementor-widget elementor-widget-image\" data-id=\"69294ea\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad85b91 elementor-widget elementor-widget-text-editor\" data-id=\"ad85b91\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El &#034;on&#034; y &#034;off&#034; de las operaciones se realiza a trav\u00e9s de la conmutaci\u00f3n de circuitos, y un conjunto de totalmente y completamente fuera de pasivo de las se\u00f1ales de salida.<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La Terminal 1 est\u00e1 conectado a la l\u00ednea media de la fuente de alimentaci\u00f3n\uff1b<br \/>2. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 2 est\u00e1 activada, es &#034;off&#034; de la operaci\u00f3n.\uff1b<br \/>3. Cuando la fuente de alimentaci\u00f3n de l\u00ednea de fase y la terminal 3 est\u00e1 activada, es &#034;en la operaci\u00f3n&#034;.\uff1b<br \/>4. La Terminal 4 es el terminal com\u00fan de pasivo contactos\uff1b<br \/>5. Cuando la operaci\u00f3n de &#034;open&#034; est\u00e1 en su lugar, la terminal 5 salidas de un &#034;totalmente se\u00f1al abierta&#034;.;<br \/>6. Cuando el &#034;off&#034; en el lugar, el terminal se compila un &#034;apagado total de la se\u00f1al&#034;. \uff1b<br \/>7. En la Terminal 7 del alambre de tierra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-ebb5092 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"ebb5092\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9080197\" data-id=\"9080197\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d3aa831 elementor-widget elementor-widget-heading\" data-id=\"d3aa831\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo G: DC circuito de control pasivo con interruptor de contacto<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3259f4b elementor-widget elementor-widget-image\" data-id=\"3259f4b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-g-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7109c8 elementor-widget elementor-widget-text-editor\" data-id=\"a7109c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De acuerdo a la unidireccional de la conductividad del diodo, por los desplazamientos de los aspectos positivos y negativos de los electrodos de la fuente de alimentaci\u00f3n de CC, el &#034;on&#034; y &#034;off&#034; de las operaciones se realizan y un conjunto de totalmente y completamente fuera de pasivo de las se\u00f1ales de salida.<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La Terminal 1 est\u00e1 conectado al electrodo positivo de la fuente de alimentaci\u00f3n y el terminal 2 es &#034;off&#034; operaci\u00f3n cuando est\u00e1 conectado al electrodo negativo de la fuente de alimentaci\u00f3n; la terminal 2 est\u00e1 conectado al electrodo positivo de la fuente de alimentaci\u00f3n y el terminal 1 es &#034;en la&#034; operaci\u00f3n cuando est\u00e1 conectado al electrodo negativo de la fuente de alimentaci\u00f3n.\uff1b<br \/>2. La Terminal 3 es el terminal com\u00fan de pasivo contactos\uff1b<br \/>3. Cuando la operaci\u00f3n de &#034;open&#034; est\u00e1 en su lugar, el terminal tiene una &#034;totalmente se\u00f1al abierta&#034;.;<br \/>4. Cuando el &#034;off&#034; en el lugar, la terminal 5 salidas de un &#034;apagado total de la se\u00f1al&#034;.;<br \/>5. En la Terminal 7 del alambre de tierra.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0934aa3\" data-id=\"0934aa3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c9aedd elementor-widget elementor-widget-text-editor\" data-id=\"7c9aedd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Al llevar a cabo una investigaci\u00f3n en el sitio del proyecto, puede contactar con nuestra empresa de servicio t\u00e9cnico de personal tan pronto como sea posible para investigar las fallas y determinar la soluci\u00f3n.<\/em><br \/><em>N\u00famero de contacto: 13026331611 (Chen Gong)<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u8d85\u5c0f\u7cfb\u5217\u7684\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a DCL-02A \/ DCL-02B \/ DCL-02G 1\u3001\u5e38 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5251,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[374,375,387,34,373],"class_list":["post-6033","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-dcl-02","tag-dcl-02-on-off","tag-trouble-shooting-guide","tag-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/media\/5251"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}