{"id":5363,"date":"2023-05-31T13:47:30","date_gmt":"2023-05-31T05:47:30","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5363"},"modified":"2024-11-12T11:18:28","modified_gmt":"2024-11-12T03:18:28","slug":"setting-switch-actuator","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/es_mx\/support\/ta-actuator\/setting-switch-actuator","title":{"rendered":"C\u00f3mo configurar el interruptor de tipo de actuador con el bit-funci\u00f3n de env\u00edo?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5363\" class=\"elementor elementor-5363\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9d3f5d6 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"9d3f5d6\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cc56700\" data-id=\"cc56700\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-24e61c6 elementor-widget elementor-widget-text-editor\" data-id=\"24e61c6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><a href=\"#step1\"><span style=\"text-decoration: underline;\">Instalaci\u00f3n mec\u00e1nica<\/span><\/a><\/li><li><a href=\"#step2\"><span style=\"text-decoration: underline;\">Ubicaci\u00f3n del transmisor descripci\u00f3n del panel<\/span><\/a><\/li><li><a href=\"#step3\"><span style=\"text-decoration: underline;\">La depuraci\u00f3n y el establecimiento de<\/span><\/a><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-583b268 elementor-widget elementor-widget-heading\" data-id=\"583b268\" data-element_type=\"widget\" id=\"step1\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Instalaci\u00f3n mec\u00e1nica<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be92113 elementor-widget elementor-widget-text-editor\" data-id=\"be92113\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>referencia <a href=\"\/es_mx\/faq\/actuator\/how-to-install-a-actuator-on-a-valve\/\">C\u00f3mo instalar el actuador a la v\u00e1lvula<\/a>, Instalar el actuador el\u00e9ctrico correctamente en el cuerpo de la v\u00e1lvula, y ejecutarlo manualmente para confirmar si el funcionamiento es normal.<\/li>\n<li>\n<p>referencia<a href=\"\/es_mx\/faq\/actuator\/how-to-set-up-a-electric-switch-type-actuator-valve\/\"> C\u00f3mo configurar un tipo de interruptor el\u00e9ctrico de la v\u00e1lvula<\/a>, Hacer ajustes correctos para la toma de l\u00edmites (fuera de plazo CLS, en el l\u00edmite OLS) y la mec\u00e1nica de los l\u00edmites del actuador el\u00e9ctrico<\/p>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb7186b elementor-widget elementor-widget-text-editor\" data-id=\"eb7186b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Recordatorio especial\uff1a<\/p>\n<ul>\n<li>Si no hay requisitos especiales, el viaje del \u00e1ngulo entre la posici\u00f3n completamente cerrada y la posici\u00f3n de apertura completa del actuador es de 90\u00b0 durante f\u00e1brica de puesta en marcha. La correspondiente corriente de salida cuando est\u00e1 completamente apagado es de 4mA, y la correspondiente corriente de salida cuando est\u00e1 completamente en es de 20mA.<\/li>\n<li>El grado de apertura del potenci\u00f3metro se ha considerado la situaci\u00f3n en la que el completo cierre de la posici\u00f3n y la plena apertura de la posici\u00f3n puede cambiar durante la puesta en servicio de la v\u00e1lvula, lo cual el \u00e1rea de trabajo del potenci\u00f3metro a cambio, por lo que generalmente es prohibido a los usuarios ajustar el potenci\u00f3metro y el potenci\u00f3metro de engranajes.<\/li>\n<li>Por favor, conecte el terminal de bloques correctamente como se muestra en la siguiente figura.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bff35e6 elementor-widget elementor-widget-heading\" data-id=\"bff35e6\" data-element_type=\"widget\" id=\"step2\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Descripci\u00f3n de la ubicaci\u00f3n del transmisor panel<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-198ff2d elementor-widget elementor-widget-image\" data-id=\"198ff2d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"797\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-setting-a-switch-actuator-with-position-feedback\/images\/position-feedback-setting.webp\" class=\"attachment-full size-full wp-image-5365\" alt=\"\u5982\u4f55\u8bbe\u7f6e\u6b66\u6c49\u534e\u6613\u4f4d\u53d1\u578b \u6267\u884c\u5668\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-setting-a-switch-actuator-with-position-feedback\/images\/position-feedback-setting.webp 800w, https:\/\/www.dcl-controls.com\/content\/dam\/faq\/actuator\/how-to-setting-a-switch-actuator-with-position-feedback\/images\/position-feedback-setting-12x12.webp 12w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aab9a9 elementor-widget elementor-widget-text-editor\" data-id=\"2aab9a9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li>Ajustable con potenci\u00f3metro\uff1a<ul><li>&#034;Completo&#034;, &#034;posici\u00f3n cero&#034;, cuando la v\u00e1lvula est\u00e1 completamente abierta o completamente cerrada, se utiliza para ajustar su correspondiente corriente de salida de 20 ma o 4 ma.<\/li><\/ul><\/li><li>Indicador de luz\uff1a<ul><li>L1: Rojo, indicador de encendido, la luz est\u00e1 encendida cuando el transmisor est\u00e1 conectado a la fuente de alimentaci\u00f3n\uff1b<\/li><li>L2: Verde, la v\u00e1lvula est\u00e1 abierta, la luz est\u00e1 en\uff1b<\/li><li>L3: Verde, la v\u00e1lvula est\u00e1 desactivada, la luz est\u00e1 en\uff1b<\/li><\/ul><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e4bc95 elementor-widget elementor-widget-heading\" data-id=\"8e4bc95\" data-element_type=\"widget\" id=\"step3\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. La depuraci\u00f3n y el establecimiento de<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-671e7a0 elementor-widget elementor-widget-text-editor\" data-id=\"671e7a0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li>Determinaci\u00f3n de la posici\u00f3n de en medio del potenci\u00f3metro<\/li><li>La corriente de salida de correcci\u00f3n<ul><li>La posici\u00f3n del generador ha sido corregida en la f\u00e1brica, y por lo general no requiere ajuste por el usuario. Si la corriente de salida de la v\u00e1lvula cuando est\u00e1 completamente abierta o completamente cerrada no es a 20 ma o 4 ma, y el error es mayor de 1%, que necesita ser ajustado. Se puede corregir de la siguiente manera: Conecte un 20mADC amper\u00edmetro a la salida de la se\u00f1al de terminaci\u00f3n, cierre completamente la v\u00e1lvula, y utilice un peque\u00f1o destornillador para ajustar el nivel de &#034;cero&#034; potenci\u00f3metro., Observar el amper\u00edmetro de la pantalla, cuando la salida es mayor que 4 ma, gire lentamente hacia la derecha, y viceversa, gire lentamente en sentido antihorario hasta que el amper\u00edmetro muestra de 4 ma (\u00b10.02); abrir completamente la v\u00e1lvula, utilice un peque\u00f1o destornillador para ajustar el &#034;completo&#034; posici\u00f3n de potenci\u00f3metro, observar el amper\u00edmetro de la pantalla, cuando la salida es mayor que 20mA, gire lentamente en sentido antihorario directionRotate, por el contrario, gire lentamente en sentido horario hasta que el amper\u00edmetro muestra 20mA (\u00b10.02) y la corriente de salida de correcci\u00f3n se ha completado.<\/li><\/ul><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ed6a17 elementor-widget elementor-widget-text-editor\" data-id=\"4ed6a17\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Observaciones: Cuando la correcci\u00f3n de la corriente de salida, primero debe ajustar el &#034;bit cero&#034; y, a continuaci\u00f3n, ajuste el &#034;bits completo&#034;, de lo contrario har\u00e1 que la posici\u00f3n del generador a fallar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-8fc9a0d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8fc9a0d\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c131ee3\" data-id=\"c131ee3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8d1612e elementor-widget elementor-widget-heading\" data-id=\"8d1612e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/es_mx\/tech\/set-up-dcl-valve\/\">Anterior: C\u00f3mo configurar un tipo de interruptor el\u00e9ctrico de la v\u00e1lvula?<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-a2d79e0\" data-id=\"a2d79e0\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a3ffde8 elementor-widget elementor-widget-heading\" data-id=\"a3ffde8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/es_mx\/tech\/set-up-dcl-actuator\/\">Siguiente: C\u00f3mo configurar un ajustable el\u00e9ctrico de la v\u00e1lvula?<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u673a\u68b0\u5b89\u88c5 \u4f4d\u7f6e\u53d1\u9001\u5668\u9762\u677f\u8bf4\u660e \u8c03\u8bd5\u4e0e\u8bbe\u7f6e 1\u3001 \u673a\u68b0\u5b89\u88c5 \u53c2\u7167 \u5982\u4f55\u5c06\u6267\u884c\u5668\u5b89\u88c5\u5230\u9600\u95e8\u4e0a\uff0c\u5c06\u7535\u52a8\u6267\u884c\u673a\u6784\u6b63\u786e\u5b89 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5366,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[334],"tags":[378,379,44,34,393,42,41],"class_list":["post-5363","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ta-actuator","tag-on-off-actuator","tag-on-off-actuator-fb","tag-fast-move-actuator","tag-actuator","tag-user-manual","tag-general-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/posts\/5363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/comments?post=5363"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/posts\/5363\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/media\/5366"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/media?parent=5363"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/categories?post=5363"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_mx\/wp-json\/wp\/v2\/tags?post=5363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}