{"id":6035,"date":"2023-08-03T20:35:14","date_gmt":"2023-08-03T12:35:14","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6035"},"modified":"2025-04-18T11:35:21","modified_gmt":"2025-04-18T03:35:21","slug":"servo-actuator","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/es_es\/support\/mr-actuator\/servo-actuator","title":{"rendered":"Los fallos m\u00e1s comunes y soluci\u00f3n de problemas de actuadores ajustable"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6035\" class=\"elementor elementor-6035\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2181a43 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"2181a43\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3cb5598\" data-id=\"3cb5598\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8236d13 elementor-widget elementor-widget-text-editor\" data-id=\"8236d13\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este asistente es adecuado para ajustables actuadores de DCL a prueba de explosi\u00f3n serie\/ordinario de la serie\/apertura r\u00e1pida de la serie. Los modelos son como sigue\uff1a<\/p><ul><li>Ordinarias series: DCL-05E\/DCL-10E\/DCL-20E\/DCL-40LO\/DCL-60E\/DCL-100E\/DCL-160E\/DCL-250E<\/li><li>A prueba de explosi\u00f3n serie: DCL-Ex05E\/DCL-Ex10E\/DCL-Ex20E\/DCL-Ex40E\/DCL-Ex60E<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9638125 elementor-widget elementor-widget-image\" data-id=\"9638125\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Actuators\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp 696w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-300x259.webp 300w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-14x12.webp 14w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-655c1c0 elementor-widget elementor-widget-heading\" data-id=\"655c1c0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Los fallos m\u00e1s comunes y los m\u00e9todos de soluci\u00f3n de problemas.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78d5a5f elementor-widget elementor-widget-shortcode\" data-id=\"78d5a5f\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-34\" class=\"tablepress tablepress-id-34 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">la culpa<\/th><th class=\"column-2\">Posible causa<\/th><th class=\"column-3\">M\u00e9todo de exclusi\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"6\" class=\"column-1\">El actuador no se enciende o apaga cuando se inicia por primera vez<\/td><td class=\"column-2\">1. Un cableado incorrecto<\/td><td class=\"column-3\">Compruebe si el cableado es correcto de acuerdo al diagrama de cableado del actuador?<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. Una alimentaci\u00f3n incorrecta<\/td><td class=\"column-3\">Confirme que el voltaje de salida de la fuente de alimentaci\u00f3n es de \u00b110% de la tensi\u00f3n nominal del actuador, y la corriente de salida es de 3 veces la corriente nominal del actuador.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. SA no se establece en 1 o 3 marchas<\/td><td class=\"column-3\">Comprobar y ajustar el SA para el 1er o 3er nivel.<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. El interruptor de parada de emergencia se desconecta (para actuadores equipados con funci\u00f3n de parada de emergencia)<\/td><td class=\"column-3\">Verificaci\u00f3n y encienda el interruptor de parada de emergencia.<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. La se\u00f1al de entrada est\u00e1 fuera del rango<br \/>\nSe\u00f1al de corriente: 4~20mA<br \/>\nSe\u00f1al de voltaje: 0~10V<\/td><td class=\"column-3\">Utilice un mult\u00edmetro para medir el voltaje entre los m\u00f3dulos de control P3 y P4, y compruebe si la tensi\u00f3n est\u00e1 en la siguiente gama\uff1a<br \/>\nSe\u00f1al de corriente: 0.88 V~4.4 V<br \/>\nSe\u00f1al de voltaje: 0~10V<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-2\">6. Todas y todos se establecen en la misma posici\u00f3n.<\/td><td class=\"column-3\">referencia<a href=\"\/es_es\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;C\u00f3mo configurar un ajustable el\u00e9ctrico de la v\u00e1lvula? \u300b<\/a> <b>Trazo de calibraci\u00f3n<\/b> En la pieza, totalmente en\/fullyoff posici\u00f3n se establece correctamente.<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td rowspan=\"4\" class=\"column-1\">Antes de que el actuador ejecuta a la posici\u00f3n de destino, deje de<\/td><td class=\"column-2\">1. V\u00e1lvula de estancamiento<\/td><td class=\"column-3\">Compruebe si la v\u00e1lvula se atasca, eliminar la atascado y vuelva a intentarlo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-2\">2. Potencial de s\u00f3lidos en el l\u00edquido a medio hacer que la v\u00e1lvula se estancan.<\/td><td class=\"column-3\">Compruebe si hay s\u00f3lidos atrapados en el medio fluido, eliminar la v\u00e1lvula atascada, e int\u00e9ntelo de nuevo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">3. Totalmente en o totalmente fuera de ajuste est\u00e1 en la posici\u00f3n de en medio, lo cual es incorrecto.<\/td><td class=\"column-3\">referencia<a href=\"\/es_es\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;C\u00f3mo configurar un ajustable el\u00e9ctrico de la v\u00e1lvula? \u300b<\/a> <b>Trazo de calibraci\u00f3n<\/b> En la pieza, totalmente en\/fullyoff posici\u00f3n se establece correctamente.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">4. La calibraci\u00f3n de la se\u00f1al de entrada de gama es incorrecta.<\/td><td class=\"column-3\">referencia<a href=\"\/es_es\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;C\u00f3mo configurar un ajustable el\u00e9ctrico de la v\u00e1lvula? \u300b<\/a> <b>Entrada de la se\u00f1al de calibraci\u00f3n<\/b> En parte, la entrada de rango de se\u00f1al est\u00e1 correctamente calibrado.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Usando el mango, el actuador no puede ser rotado<\/td><td class=\"column-2\">1. Potencial de s\u00f3lidos en el medio fluido causa la v\u00e1lvula de quedar atrapado.<\/td><td class=\"column-3\">Compruebe si hay s\u00f3lidos atrapados en el medio fluido, eliminar la v\u00e1lvula atascada, e int\u00e9ntelo de nuevo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. V\u00e1lvula atascada<\/td><td class=\"column-3\">Compruebe si la v\u00e1lvula se atasca, eliminar la atascado y vuelva a intentarlo despu\u00e9s de que el actuador es enfriado por la protecci\u00f3n de sobrecarga.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. El actuador de la desaceleraci\u00f3n mecanismo est\u00e1 da\u00f1ado.<\/td><td class=\"column-3\">Retire el actuador de la v\u00e1lvula y gire la manija. Si no se puede girar, reempl\u00e1celo con un nuevo actuador.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Incorrecta de la se\u00f1al de retroalimentaci\u00f3n<\/td><td class=\"column-2\">1. L\u00ednea abierta<\/td><td class=\"column-3\">Utilice un mult\u00edmetro para medir el voltaje entre los m\u00f3dulos de control P5 y P6. Si el valor medido es &gt;18V, la se\u00f1al es abierta. Comprobar y corregir problemas en la l\u00ednea.<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. La impedancia de entrada en el extremo receptor de la se\u00f1al de retroalimentaci\u00f3n es demasiado grande.<\/td><td class=\"column-3\">Medir y confirmar la impedancia de entrada en el extremo receptor de la se\u00f1al de realimentaci\u00f3n<800\u6b27\u59c6<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. La se\u00f1al de realimentaci\u00f3n est\u00e1 mal calibrado.<\/td><td class=\"column-3\">1 referencia<a href=\"\/es_es\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;C\u00f3mo configurar un ajustable con V\u00e1lvula El\u00e9ctrica&#034;<\/a> <b>La corriente de salida de correcci\u00f3n<\/b> Parte, calibrar la se\u00f1al de salida.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-34 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b181a03 elementor-widget elementor-widget-heading\" data-id=\"b181a03\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Por favor, compruebe si la aplicaci\u00f3n de las condiciones de satisfacer los requisitos de par\u00e1metro.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8135be elementor-widget elementor-widget-text-editor\" data-id=\"b8135be\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 El actuador el\u00e9ctrico puede fallar debido a un uso indebido o en virtud de la aplicaci\u00f3n incorrecta de las condiciones. En virtud de la aplicaci\u00f3n de las condiciones definidas en la especificaci\u00f3n de producto, en el largo plazo de la operaci\u00f3n libre de problemas del actuador estar\u00e1 garantizada.<\/p><ul><li><strong>Tensi\u00f3n de alimentaci\u00f3n\uff1a<\/strong>El voltaje de la fuente de alimentaci\u00f3n debe estar dentro de la nominal rango de voltaje de operaci\u00f3n del actuador. Sobretensi\u00f3n o subtensi\u00f3n puede causar la vida del actuador a reducirse.<\/li><li><span style=\"font-weight: bold;\">La oferta actual\uff1a<\/span>Desde la corriente de arranque del motor es mucho mayor que la corriente nominal. Para garantizar el funcionamiento fiable del actuador, por favor, utilice una fuente de alimentaci\u00f3n con una capacidad de salida de corriente mayor que 3 veces la corriente nominal del actuador.<\/li><li><strong>la temperatura\uff1a<\/strong>Aseg\u00farese de que el actuador opera dentro de la nominal rango de temperatura de funcionamiento. El uso del actuador en un entorno que supera la tensi\u00f3n nominal rango de temperatura de operaci\u00f3n puede conducir a una mala funci\u00f3n de actuador o disminuci\u00f3n de la vida \u00fatil, y en \u00faltima instancia conducir a la falla del actuador.<\/li><li><strong>medio ambiente\uff1a<\/strong>El DCL interruptor de tipo de actuador tiene un grado de protecci\u00f3n IP67 resistente a la intemperie clasificaci\u00f3n. Por lo general, adecuado para aplicaciones en interiores y exteriores. Proporcionar un cierto grado de lluvia y las salpicaduras de protecci\u00f3n. Proteger el actuador de la lluvia, la nieve, el hielo y la luz ultravioleta (luz solar) generalmente se prolonga la vida \u00fatil del producto. Muy ambientes corrosivos puede causar el fallo prematuro de los equipos electr\u00f3nicos. No use no es a prueba de explosi\u00f3n serie de actuadores en una prueba de explosiones de medio ambiente.<\/li><li><strong>El poder-sobre la continuidad de la tasa\uff1a<\/strong>El poder-sobre la continuidad de la tasa de la DCL actuador de conmutaci\u00f3n es de 70% (pasa de 42 segundos por minuto y deben estar apagados durante 18 segundos). M\u00e1s del 70% de la energ\u00eda en la continuidad de la tarifa de la causa el motor para entrar de protecci\u00f3n de sobrecalentamiento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffb6e36 elementor-widget elementor-widget-heading\" data-id=\"ffb6e36\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Compruebe si el cableado del actuador es correcta<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-79e7d80 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"79e7d80\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-e574526\" data-id=\"e574526\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-146faf8 elementor-widget elementor-widget-heading\" data-id=\"146faf8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tipo E: con el controlador de servos (ajustable tipo)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b2af77 elementor-widget elementor-widget-image\" data-id=\"3b2af77\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e-15x12.webp 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6dc6fb elementor-widget elementor-widget-text-editor\" data-id=\"f6dc6fb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Entrada: 4~20mA \/ 0~10V arbitraria de configuraci\u00f3n.<\/p><p>Salida: 4~20mA \/ 0~10V arbitraria de configuraci\u00f3n.<\/p><p>Autob\u00fas: Modbus \/ PUEDE<\/p><p>Internet de las Cosas: WIFI\/LoRA\/4G DTU<\/p><p><strong>Instrucciones de cableado\uff1a<\/strong><br \/>1. La &#034;N&#034; en la entrada de la &#034;fuente de ALIMENTACI\u00d3N&#034; est\u00e1 conectado a la l\u00ednea media, y la &#034;L&#034; est\u00e1 conectado a la l\u00ednea de fase.\uff1b<br \/>2. La &#034;se\u00f1al de entrada&#034; terminal est\u00e1 conectado al polo negativo de la se\u00f1al de entrada, y el &#034;+&#034; terminal est\u00e1 conectado al polo positivo de la se\u00f1al de entrada.\uff1b<br \/>3. La &#034;se\u00f1al de salida&#034; terminal est\u00e1 conectado al electrodo negativo de la DC amper\u00edmetro, y el &#034;+&#034; terminal est\u00e1 conectado al electrodo positivo de la DC amper\u00edmetro.<\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8bc6e6 elementor-widget elementor-widget-text-editor\" data-id=\"b8bc6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Al llevar a cabo una investigaci\u00f3n en el sitio del proyecto, puede contactar con nuestra empresa de servicio t\u00e9cnico de personal tan pronto como sea posible para investigar las fallas y determinar la soluci\u00f3n.<\/em><br \/><em>N\u00famero de contacto: 13026331611 (Chen Gong)<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u9632\u7206\u7cfb\u5217\/\u666e\u901a\u7cfb\u5217\/\u5feb\u5f00\u7cfb\u5217\u7684\u8c03\u8282\u578b\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a \u666e\u901a\u7cfb\u5217\uff1aDCL-05E\/DCL-1 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6918,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[387,44,34,42,377,41],"class_list":["post-6035","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-trouble-shooting-guide","tag-fast-move-actuator","tag-actuator","tag-general-actuator","tag-servo-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/posts\/6035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/comments?post=6035"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/posts\/6035\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/media\/6918"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/media?parent=6035"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/categories?post=6035"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/es_es\/wp-json\/wp\/v2\/tags?post=6035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}