{"id":6541,"date":"2023-09-18T19:31:17","date_gmt":"2023-09-18T11:31:17","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6541"},"modified":"2025-04-18T14:03:14","modified_gmt":"2025-04-18T06:03:14","slug":"gb-t-3369-2-2008-iec-60381-2-1978","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/da_dk\/support\/ts-actuator\/gb-t-3369-2-2008-iec-60381-2-1978","title":{"rendered":"Elektrisk aktuator sp\u00e6ndingssignal (1~5V, 0~5V,0~10V,-10V~10V) g\u00e6ldende standard, GB\/T 3369.2-2008\/IEC 60381-2:1978"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6541\" class=\"elementor elementor-6541\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4ad6800 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4ad6800\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-448b26a\" data-id=\"448b26a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>G\u00e6ldende standard for elektrisk aktuator sp\u00e6ndingssignal (1~5V, 0~5V, 0~10V, -10V~10V)\uff1a<\/p><ul><li>Analoge signaler for proceskontrol systemer, Del 2: DC sp\u00e6nding signaler (GB\/T 3369.2\u20142008\/IEC 60381-2:1978)<\/li><li><p>Analoge signaler for process control systems-Part 2;Direkte sp\u00e6nding ignals(IEC 60381-2 - 1978,1 DT)<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-314b810 elementor-widget elementor-widget-heading\" data-id=\"314b810\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Forord<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d95a9b elementor-widget elementor-widget-image\" data-id=\"6d95a9b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"763\" height=\"1031\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/tech\/images\/gb-t-3369-2-2008-iec-60381-2-1978.webp\" class=\"attachment-full size-full wp-image-6542\" alt=\"GB\/T 3369.2\u20142008\/IEC 60381-2:1978 - \u8fc7\u7a0b\u63a7\u5236\u7cfb\u7edf\u7528\u6a21\u62df\u4fe1\u53f7 \u7b2c2\u90e8\u5206\uff1a\u76f4\u6d41\u7535\u538b\u4fe1\u53f7\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/tech\/images\/gb-t-3369-2-2008-iec-60381-2-1978.webp 763w, https:\/\/www.dcl-controls.com\/content\/dam\/tech\/images\/gb-t-3369-2-2008-iec-60381-2-1978-9x12.webp 9w\" sizes=\"(max-width: 763px) 100vw, 763px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-303746d elementor-widget elementor-widget-text-editor\" data-id=\"303746d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>GB\/T3369 &#034;Analoge Signaler for Process Control Systems&#034; er opdelt i f\u00f8lgende to dele\uff1a<br>Del 1; DC aktuelt signal\uff1b<br>Del 2: DC sp\u00e6nding Signal<br>Denne del er opdelt i Del 2 GB\/T 3369.<br>Denne del svarer til IEC 60381-2:1978 &#034;Analoge Signaler for proceskontrol Systemer, Del 2: DC-Sp\u00e6nding-Signaler&#034; (engelsk version).<br>If\u00f8lge GB\/T1.1-2000 &#034;standardiseringsarbejde Retningslinjer, Del 1: Standard Struktur og Skrivning Regler&#034;, de f\u00f8lgende redaktionelle \u00e6ndringer er foretaget i henhold til IEC 60381-2:1978\uff1a<br>a) &#034;Denne standard&#034; blev \u00e6ndret til &#034;denne side&#034;;<br>b) Slettet forord af IEC 60381-2:1978\uff1b<br>c) Hvor der er &#034;IEC60381&#034;, \u00e6ndre det til &#034;GB\/T, 3369&#034;;<br>d) Anvende komma&#034;. &#034;I stedet for komma som decimal-punkt&#034;, &#034;Denne del erstatter GB\/T 3370-1989 &#034;Analog DC Sp\u00e6nding Signaler for Industriel Automation Instrumenter&#034;.<br>Sammenlignet med GB\/T 3370-1989, de vigtigste \u00e6ndringer i denne del er som f\u00f8lger. Standard navn er \u00e6ndret fra &#034;Analog DC sp\u00e6nding signal til Industriel automation Instrumenter&#034; til &#034;Analog Signal for Process Control System Del 2: DC Sp\u00e6nding Signal&#034;; &#034;Denne standard&#034; er \u00e6ndret til &#034;Denne side.&#034;;<br>Anvendelsesomr\u00e5de: GB\/T 3370-1989 henviser til brug af IEC 60381-2:1979, omfanget af anvendelsen er industriel automation instrumenter, og denne standard svarer til anvendelse af IEC 60381-2:1979, omfanget af anvendelsen er industriel proces, m\u00e5ling og kontrol systemer (Kapitel 1 GB\/T 3370-1989; Kapitel 1 om denne del);<br>\u00c6ndre &#034;industriel automation instrument&#034; i anvendelsesomr\u00e5det til &#034;component&#034; (Kapitel 1, GB\/T 3370-1989; Kapitel 1 om denne del); &#034;output&#034; ripple &#034;indhold&#034; og &#034;output AC komponent&#034; er blevet slettet i den terminologi og definition afsnit, og &#034;den m\u00e5lte v\u00e6rdi af analog DC sp\u00e6nding signal m\u00e5lt&#034; er blevet tilf\u00f8jet. V\u00e6rdien af en analog direct sp\u00e6nding signal&#034;, &#034;Load impedans&#034;, &#034;Ripple &#034; indhold&#034;, &#034;signal f\u00e6lles linje, f\u00e6lles signal&#034;, &#034;signal isolation signal isolation&#034; (GB\/T 3370-1989 1.6, 1.7; 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del, 2.3 i denne del,2.7, 2.8, 2.9, 2.10);<br>Det sp\u00e6nder af &#034;0\uff5e+10&#034; og &#034;-10\uff5e+10&#034; er blevet tilf\u00f8jet til &#034;den vifte af DC sp\u00e6nding signaler i Tabel 1&#034; (Tabel 1 GB\/T 3370-1989; Tabel 1 i denne del).<br>Denne del er foresl\u00e5et af Kina Maskiner Industry Federation.<br>Denne del er central, som den anden Sub-Tekniske Udvalg for Nationale Tekniske Udvalg for Standardisering af Industrielle Proces, M\u00e5ling og Kontrol. Udarbejdelsen enhed, der er ansvarlig for denne del: Sydvest University, Kina Silian Instrumentering Gruppe<br>Deltagende redaktionelle enheder i denne del: Institut for Omfattende Teknologi og \u00d8konomi af Maskiner til Industri Instrumentering, og Beijing Institute of Maskiner til Automatisering Industrien. De vigtigste ophavsm\u00e6ndene til denne del: Liu Feng, Pan Dongbo, Yu Zhang, Liu Jin\uff0c<br>Deltagende ophavsm\u00e6ndene i denne del: Feng Xiaosheng og Xie Bingbing.<br>De tidligere udgivelser af de standarder, der anvendes i dette afsnit, er\uff1a<br>\u2014GB. 3370\u2014 1982;<br>\u2014GB\/T 3370-1989.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b08d07 elementor-widget elementor-widget-heading\" data-id=\"0b08d07\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Analog signal til proces kontrol system<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e183b40 elementor-widget elementor-widget-text-editor\" data-id=\"e183b40\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Del 2: DC sp\u00e6nding Signal<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e09978a elementor-widget elementor-widget-heading\" data-id=\"e09978a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1 r\u00e6kke<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43fc67c elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"43fc67c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Denne del er egnet til analog DC sp\u00e6nding signaler, der bruges til at overf\u00f8re oplysninger mellem system-komponenter i den industrielle proces, m\u00e5ling og kontrol systemer.<br \/>I mods\u00e6tning til analog DC aktuelt signal, der er specificeret i GB\/T 3369.1-2008, analog DC sp\u00e6nding signal, der er angivet i dette afsnit, skal ikke bruges til transmission over lange afstande.<br \/>Dette afsnit g\u00e6lder ikke for signaler, der bruges udelukkende inde i en komponent.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d21c427 elementor-widget elementor-widget-heading\" data-id=\"d21c427\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2 Termer og definitioner<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-306069e elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"306069e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00f8lgende termer og definitioner, der g\u00e6lder for dette afsnit.<br \/><strong>2.1<\/strong><br \/><strong>Komponenter industrielle proces, m\u00e5ling og kontrol systemer clements af industriel proces m\u00e5ling nd kontrol systemer <\/strong><\/p><p>En funktionel enhed til konvertering, overf\u00f8rsel eller behandling m\u00e5lte v\u00e6rdier, kontrol m\u00e6ngder, kontrol-variabler, og reference-variable, og en integreret kombination enhed.<br \/><strong>2.2<\/strong><br \/><strong>Analog direct sp\u00e6nding signal analog direct sp\u00e6ndingssignal<\/strong><br \/>En DC-sp\u00e6nding-signal, som bruges til at sende eller behandle oplysninger, der \u00e6ndres i en kontinuerlig m\u00e5de i henhold til en eller flere fysiske m\u00e6ngder.<br \/><strong>2.3<\/strong><br \/><strong>M\u00e5lt v\u00e6rdien af en analog direct sp\u00e6nding signal m\u00e5lt v\u00e6rdien af en analog direct sp\u00e6ndingssignal<\/strong><br \/>Den gennemsnitlige v\u00e6rdi inden for den angivne varighed.<br \/><strong>2.4<\/strong><br \/><strong>Nedre gr\u00e6nse nedre gr\u00e6nse<\/strong><br \/>Signal sp\u00e6ndingen svarer til den mindste v\u00e6rdi af DC-sp\u00e6nding signal.<br \/><strong>2.5<\/strong><br \/><strong>\u00d8vre gr\u00e6nse<\/strong><br \/>Signalet sp\u00e6nding, der svarer til den maksimale v\u00e6rdi for DC-sp\u00e6nding signal.<br \/><strong>2.6<\/strong><br \/><strong>Udvalg af en analog DC sp\u00e6nding signal r\u00e6kkevidde af et analogt signal DC-sp\u00e6nding<\/strong><br \/>Intervallet bestemt af den nedre og \u00f8vre gr\u00e6nser for signalet sp\u00e6nding.<br \/><strong>2.7<\/strong><br \/><strong>Load impedans<\/strong><br \/>Summen af impedansen for alle de tilsluttede modtagere.<br \/><strong>2.8<\/strong><br \/><strong>Ripple indhold ripple indhold<\/strong><br \/>Forholdet mellem peak-to-peak af AC-komponenter til den \u00f8vre gr\u00e6nse for DC-sp\u00e6nding signal.<br \/><strong>2.9<\/strong><br \/><strong>Signal f\u00e6lles linje, f\u00e6lles signal<\/strong><br \/>Flere signalkredsl\u00f8b kan have en f\u00e6lles elektrisk tilslutning linje, og den f\u00e6lles signal linje kan v\u00e6re jordforbundet eller uden jordforbindelse.<\/p><p><strong>2.10<\/strong><br \/><strong>Signal signal isolation isolation<\/strong><br \/>Der er ingen elektrisk forbindelse mellem det signal, kredsl\u00f8b og andre kredsl\u00f8b og jorden.<br \/><br \/><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66d56c2 elementor-widget elementor-widget-heading\" data-id=\"66d56c2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3 Tekniske krav<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0da31f0 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"0da31f0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>3.1 udvalg af analog DC sp\u00e6nding signaler<\/strong><br \/>Tabel 1 viser den r\u00e6kke af analog DC sp\u00e6nding signal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17b0424 elementor-widget elementor-widget-shortcode\" data-id=\"17b0424\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-49\" class=\"tablepress tablepress-id-49 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th colspan=\"2\" class=\"column-1\">Tabel 1 r\u00e6kken af DC sp\u00e6nding signaler<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Nedre gr\u00e6nse\/V<\/td><td class=\"column-2\">\u00d8vre gr\u00e6nse\/V<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">+1<br \/>\n0<br \/>\n0<br \/>\n-10<\/td><td class=\"column-2\">+5(a)<br \/>\n+5(a)<br \/>\n+10(a)<br \/>\n+10(b)<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">en sp\u00e6nding signal kan opn\u00e5s fra analog DC aktuelt signal, der er specificeret i GB\/T 3369.1\u20142008.<br \/>\nb sp\u00e6ndingssignal er en fysisk m\u00e6ngde, der kan v\u00e6re repr\u00e6senteret ved bipolar egenskaber<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-49 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fb269b elementor-widget elementor-widget-text-editor\" data-id=\"3fb269b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>3.2 Ripple indhold<\/strong><br \/>N\u00e5r du bruger en krusning-gratis DC str\u00f8mforsyning, f\u00f8lgende v\u00e6rdier skal v\u00e6re angivet\uff1a<\/p><ul><li>Ripple indhold og hyppighed i systemet komponenter\uff1b<\/li><li>Den st\u00f8j, der genereres inde i systemet, komponenter og deres hyppighed.<\/li><\/ul><p>Ripple indhold genereres af krusning af DC-str\u00f8mforsyningen skal ogs\u00e5 v\u00e6re angivet.<br \/><strong>3.3 Signal f\u00e6lles linje<\/strong><br \/>For unipolar signaler, og den negative pol af signalet er det signal, f\u00e6lles linje. Hvis signalet f\u00e6lles linje er forbundet til en DC-str\u00f8mforsyning, skal det v\u00e6re forbundet til den negative terminal p\u00e5 str\u00f8mforsyningen.<br \/>For bipolar signaler, den neutrale terminal af signalet er det signal, f\u00e6lles linje. Hvis signalet f\u00e6lles linje er forbundet til en DC-str\u00f8mforsyning, skal det v\u00e6re forbundet til den neutrale terminal af str\u00f8mforsyningen.<br \/><strong>3.4 Jordforbindelse<\/strong><br \/>For en unipolar signal, hvis element er jordet, og den negative pol af signal og\/eller negative eller hensigtsm\u00e6ssigt neutrale terminal af DC-str\u00f8mforsyningen skal v\u00e6re jordforbundet.<br \/>For bipolar signaler, hvis element er jordet, den neutrale terminal af signal og\/eller den neutrale terminal af DC-str\u00f8mforsyningen skal v\u00e6re jordforbundet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2612ada elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"2612ada\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d8e194 elementor-widget elementor-widget-text-editor\" data-id=\"0d8e194\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Relaterede tekniske artikler\uff1a<\/p><ul><li><a href=\"\/da_dk\/tech\/why-voltage-signal-oscillate\/\">Hvorfor sp\u00e6nding-type output signal svinger under visse driftsforhold?<\/a><\/li><li><a href=\"\/da_dk\/tech\/actuator-immunity-4-20ma-vs-2-10v\/\">Stor konkurrence for anti-indblanding udf\u00f8relsen af elektriske aktuatorer (4-20mA VS 2-10V)<\/a><\/li><\/ul><p>Relaterede tekniske standarder<\/p><ul><li><a href=\"\/da_dk\/tech\/gb-t-3369-1-2008-iec-60381-1-1982\/\">GB\/T 3369.1\u20142008\/IEC 60381-1:1982 Analoge signaler for process control systems-Part 1: DC aktuelle signaler<\/a><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u7535\u52a8\u6267\u884c\u5668\u7535\u538b\u4fe1\u53f7\uff081~5V,0~5V,0~10V,-10V~10V\uff09\u9002\u7528\u6807\u51c6\uff1a \u8fc7\u7a0b\u63a7\u5236\u7cfb\u7edf\u7528\u6a21\u62df\u4fe1\u53f7 \u7b2c2 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6542,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[651],"tags":[44,34,390,42,373,41],"class_list":["post-6541","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ts-actuator","tag-fast-move-actuator","tag-actuator","tag-tech-ref","tag-general-actuator","tag-very-small-actuator-tag","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/posts\/6541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/comments?post=6541"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/posts\/6541\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/media\/6542"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/media?parent=6541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/categories?post=6541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/tags?post=6541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}