{"id":6035,"date":"2023-08-03T20:35:14","date_gmt":"2023-08-03T12:35:14","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6035"},"modified":"2025-04-18T11:35:21","modified_gmt":"2025-04-18T03:35:21","slug":"servo-actuator","status":"publish","type":"post","link":"https:\/\/www.dcl-controls.com\/da_dk\/support\/mr-actuator\/servo-actuator","title":{"rendered":"Almindelige fejl og fejlfinding af justerbare aktuatorer"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6035\" class=\"elementor elementor-6035\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2181a43 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"2181a43\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3cb5598\" data-id=\"3cb5598\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8236d13 elementor-widget elementor-widget-text-editor\" data-id=\"8236d13\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Denne guide er egnet til justerbar aktuatorer DCL eksplosionssikker serie\/almindelige series\/hurtig \u00e5bning serie. Modellerne er som f\u00f8lger\uff1a<\/p><ul><li>Almindelige series: DCL-05E\/DCL-10E\/DCL-20E\/DCL-40E\/DCL-60E\/DCL-100E\/DCL-160E\/DCL-250E<\/li><li>Eksplosionssikker serie: DCL-Ex05E\/DCL-Ex10E\/DCL-Ex20E\/DCL-Ex40E\/DCL-Ex60E<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9638125 elementor-widget elementor-widget-image\" data-id=\"9638125\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Actuators\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line.webp 696w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-300x259.webp 300w, https:\/\/www.dcl-controls.com\/content\/dam\/home\/images\/shelf-banner\/dcl-actuator-product-line-14x12.webp 14w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-655c1c0 elementor-widget elementor-widget-heading\" data-id=\"655c1c0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Almindelige fejl og fejlfinding.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78d5a5f elementor-widget elementor-widget-shortcode\" data-id=\"78d5a5f\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-34\" class=\"tablepress tablepress-id-34 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">fejl<\/th><th class=\"column-2\">Mulig \u00e5rsag<\/th><th class=\"column-3\">Udelukkelse metode<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"6\" class=\"column-1\">Aktuatoren ikke vil t\u00e6nde eller slukke, n\u00e5r det er f\u00f8rste gang<\/td><td class=\"column-2\">1. Forkert ledningsf\u00f8ring<\/td><td class=\"column-3\">Check om, at ledningsf\u00f8ringen er korrekt i henhold til ledningsdiagrammet af aktuator?<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. Forkert str\u00f8mforsyning<\/td><td class=\"column-3\">Bekr\u00e6ft, at udgangssp\u00e6ndingen af str\u00f8mforsyningen er \u00b110% af den nominelle sp\u00e6nding aktuatoren, og udgangsstr\u00f8mmen er 3 gange den nominelle str\u00f8m af aktuatoren.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. SA er ikke indstillet til 1 eller 3 gear<\/td><td class=\"column-3\">Ind og s\u00e6t SA at 1st eller 3rd gear.<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. Den n\u00f8d-stop-kontakten er afbrudt (for aktuatorer udstyret med n\u00f8dstop)<\/td><td class=\"column-3\">Ind, og drej p\u00e5 n\u00f8dstop-afbryder.<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. Indgangssignalet er uden for r\u00e6kkevidde<br \/>\nAktuelle signal: 4~20mA<br \/>\nSp\u00e6nding signal: 0~10V<\/td><td class=\"column-3\">Brug et multimeter til at m\u00e5le sp\u00e6ndingen mellem kontrol moduler P3 og P4, og kontrollere, om sp\u00e6ndingen er i den f\u00f8lgende r\u00e6kke\uff1a<br \/>\nAktuelle signal: 0.88 V~4.4 V<br \/>\nSp\u00e6nding signal: 0V~10V<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-2\">6. Alle p\u00e5 og alle off er indstillet til samme position.<\/td><td class=\"column-3\">reference<a href=\"\/da_dk\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;S\u00e5dan konfigureres en justerbar elektrisk ventil? \u300b<\/a> <b>Stroke kalibrering<\/b> I den del, fuldt p\u00e5\/fullyoff position er indstillet korrekt.<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td rowspan=\"4\" class=\"column-1\">F\u00f8r aktuatoren k\u00f8rer til m\u00e5let position, stop<\/td><td class=\"column-2\">1. Ventilen stagnation<\/td><td class=\"column-3\">Tjek, om ventilen er fast, fjerne de sidder fast, og pr\u00f8ve igen, efter at motoren er k\u00f8let af overbelastningsbeskyttelse.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-2\">2. Potentielle faste stoffer i flydende medium \u00e5rsag ventilen til at stagnere.<\/td><td class=\"column-3\">Tjek, om der er faste stoffer fast i flydende medium, fjerne ventilen sidder, og pr\u00f8ve igen, efter at motoren er k\u00f8let af overbelastningsbeskyttelse.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">3. Den er fuldt p\u00e5 eller fuldt off-indstillingen er i midterste position, som er forkert.<\/td><td class=\"column-3\">reference<a href=\"\/da_dk\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;S\u00e5dan konfigureres en justerbar elektrisk ventil? \u300b<\/a> <b>Stroke kalibrering<\/b> I den del, fuldt p\u00e5\/fullyoff position er indstillet korrekt.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">4. Kalibrering af input-signalet sortiment er forkert.<\/td><td class=\"column-3\">reference<a href=\"\/da_dk\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;S\u00e5dan konfigureres en justerbar elektrisk ventil? \u300b<\/a> <b>Input signal kalibrering<\/b> I en del, input signal interval er korrekt kalibreret.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">Ved hj\u00e6lp af de h\u00e5ndtag, aktuatoren kan ikke roteres,<\/td><td class=\"column-2\">1. Potentielle faste stoffer i flydende medium \u00e5rsag ventilen til at sidde fast.<\/td><td class=\"column-3\">Tjek, om der er faste stoffer fast i flydende medium, fjerne ventilen sidder, og pr\u00f8ve igen, efter at motoren er k\u00f8let af overbelastningsbeskyttelse.<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. Ventilen sidder<\/td><td class=\"column-3\">Tjek, om ventilen er fast, fjerne de sidder fast, og pr\u00f8ve igen, efter at motoren er k\u00f8let af overbelastningsbeskyttelse.<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. Aktuatoren deceleration mekanisme er beskadiget.<\/td><td class=\"column-3\">Fjern aktuator fra ventilen, og drej h\u00e5ndtaget. Hvis det ikke kan drejes, skal du erstatte den med en ny aktuator.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">Forkert signal feedback<\/td><td class=\"column-2\">1. \u00c5ben linje<\/td><td class=\"column-3\">Brug et multimeter til at m\u00e5le sp\u00e6ndingen mellem kontrol moduler P5 og P6. Hvis den m\u00e5lte v\u00e6rdi er &gt;18V, signalet er \u00e5ben. Find og l\u00f8s problemer.<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. Input impedans p\u00e5 den modtagende ende af feedback-signalet er for store.<\/td><td class=\"column-3\">M\u00e5le og bekr\u00e6fte input impedans p\u00e5 den modtagende ende af et signal feedback<800\u6b27\u59c6<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. Feedback signal er kalibreret forkert.<\/td><td class=\"column-3\">1 reference<a href=\"\/da_dk\/faq\/actuator\/set-up-dcl-actuator\/\">&#034;S\u00e5dan konfigureres en justerbar Elektrisk Ventil&#034;<\/a> <b>Udgangsstr\u00f8m korrektion<\/b> Del, kalibrere output signal.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-34 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b181a03 elementor-widget elementor-widget-heading\" data-id=\"b181a03\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Check venligst om ans\u00f8gningen betingelser opfylder parameter krav.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8135be elementor-widget elementor-widget-text-editor\" data-id=\"b8135be\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 Den elektriske aktuator kan mislykkes p\u00e5 grund af forkert brug eller under det forkerte program betingelser. Under de anvendelsesbetingelser, der er defineret i produkt-specifikation, den langsigtede problemfri drift af aktuatoren vil blive sikret.<\/p><ul><li><strong>Forsynings sp\u00e6nding:<\/strong>Sp\u00e6ndingen i str\u00f8mforsyningen skal v\u00e6re inden for den nominelle driftssp\u00e6nding vifte af aktuatoren. Oversp\u00e6nding eller undersp\u00e6nding kan for\u00e5rsage livet af aktuator at blive reduceret.<\/li><li><span style=\"font-weight: bold;\">Levering nuv\u00e6rende\uff1a<\/span>Da udgangspunktet nuv\u00e6rende motor er meget st\u00f8rre end den m\u00e5lte str\u00f8m. For at sikre en p\u00e5lidelig drift af aktuator, skal du bruge en str\u00f8mforsyning med en produktion med den nuv\u00e6rende kapacitet, der er st\u00f8rre end 3 gange den nominelle str\u00f8m af aktuatoren.<\/li><li><strong>temperatur:<\/strong>Sikre, at aktuatoren er i drift inden for den nominelle driftstemperatur. Brug af aktuatoren i et milj\u00f8, der overstiger den nominelle driftstemperatur, kan f\u00f8re til d\u00e5rlig aktuator funktion eller nedsat levetid, og i sidste ende f\u00f8re til svigt af aktuatoren.<\/li><li><strong>milj\u00f8\uff1a<\/strong>Den DCL skifte type aktuator er en IP67 vandt\u00e6t rating. Generelt velegnet til indend\u00f8rs eller udend\u00f8rs applikationer. Give en vis grad af regn og st\u00e6nk beskyttelse. Beskyttelse af motoren mod regn, sne, is og ultraviolet lys (sollys) normalt forl\u00e6nger levetiden af produktet. Meget korrosive milj\u00f8er kan for\u00e5rsage for tidlig svigt af elektronisk udstyr. Brug ikke ikke-eksplosionssikker r\u00e6kke aktuatorer i en eksplosionssikret milj\u00f8.<\/li><li><strong>Power-on kontinuitet sats\uff1a<\/strong>Power-on kontinuitet sats af DCL skift af aktuator er 70% (det k\u00f8rer for 42 sekunder per minut, og den skal v\u00e6re slukket i 18 sekunder). Mere end 70% af str\u00f8mmen kontinuitet sats vil f\u00e5 motoren til at indtaste overophedning beskyttelse.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffb6e36 elementor-widget elementor-widget-heading\" data-id=\"ffb6e36\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Kontrollere, om de ledninger af aktuatoren er korrekte<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-79e7d80 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"79e7d80\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-e574526\" data-id=\"e574526\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-146faf8 elementor-widget elementor-widget-heading\" data-id=\"146faf8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type E: med servo controller (justerbar type)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b2af77 elementor-widget elementor-widget-image\" data-id=\"3b2af77\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" srcset=\"https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e.webp 400w, https:\/\/www.dcl-controls.com\/content\/dam\/actuator\/images\/interface-circuit\/dcl-actuator-interface-diagram-e-15x12.webp 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6dc6fb elementor-widget elementor-widget-text-editor\" data-id=\"f6dc6fb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Input: 4~20mA \/ 0~10V vilk\u00e5rlig konfiguration.<\/p><p>Output: 4~20mA \/ 0~10V vilk\u00e5rlig konfiguration.<\/p><p>Bus: Modbus \/ KAN<\/p><p>Internet of Things: WIFI\/LoRA\/4G DTU<\/p><p><strong>Ledninger instruktioner\uff1a<\/strong><br \/>1. &#034;N&#034; p\u00e5 indgangen af &#034;POWER supply&#034; er forbundet til den midterste linje, og &#034;L&#034; er forbundet til den fase linje.\uff1b<br \/>2. &#034;Input signal&#034; terminalen er forbundet til den negative pol af input-signalet, og &#034;+&#034; terminalen er forbundet til den positive pol af input-signalet.\uff1b<br \/>3. &#034;Output signal&#034; terminalen er forbundet til den negative elektrode af DC-amperemeter, og &#034;+&#034; terminal, der er tilsluttet den positive elektrode af DC-amperemeter.<\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8bc6e6 elementor-widget elementor-widget-text-editor\" data-id=\"b8bc6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>N\u00e5r du foretager en unders\u00f8gelse p\u00e5 projektets hjemmeside, kan du kontakte vores tekniske service medarbejdere s\u00e5 hurtigt som muligt at unders\u00f8ge de fejl og finde l\u00f8sningen.<\/em><br \/><em>Kontakt nummer: 13026331611 (Chen Gong)<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u8be5\u5411\u5bfc\u9002\u7528\u4e8eDCL\u9632\u7206\u7cfb\u5217\/\u666e\u901a\u7cfb\u5217\/\u5feb\u5f00\u7cfb\u5217\u7684\u8c03\u8282\u578b\u6267\u884c\u5668\uff0c\u578b\u53f7\u5982\u4e0b\uff1a \u666e\u901a\u7cfb\u5217\uff1aDCL-05E\/DCL-1 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":6918,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[349],"tags":[387,44,34,42,377,41],"class_list":["post-6035","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-trouble-shooting-guide","tag-fast-move-actuator","tag-actuator","tag-general-actuator","tag-servo-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/posts\/6035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/comments?post=6035"}],"version-history":[{"count":0,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/posts\/6035\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/media\/6918"}],"wp:attachment":[{"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/media?parent=6035"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/categories?post=6035"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dcl-controls.com\/da_dk\/wp-json\/wp\/v2\/tags?post=6035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}